Analysis of protection system setting in 11KV distribution system / Ammar Alamshah

One of the fundamental protections used in electrical network power system is Overcurrent and Earth Fault (OCEF) protection. They have to be both sensitive and quick in minimizing the electrodynamic and thermal stress imposed on the equipment during the fault time interval. It is utmost important fo...

وصف كامل

التفاصيل البيبلوغرافية
المؤلف الرئيسي: Ammar, Alamshah
التنسيق: أطروحة
منشور في: 2020
الموضوعات:
_version_ 1849735536858628096
author Ammar, Alamshah
author_facet Ammar, Alamshah
author_sort Ammar, Alamshah
description One of the fundamental protections used in electrical network power system is Overcurrent and Earth Fault (OCEF) protection. They have to be both sensitive and quick in minimizing the electrodynamic and thermal stress imposed on the equipment during the fault time interval. It is utmost important for the relays to be capable of removing only the faulty section while keep up the flexibly to solid areas in the system. In order to achieve this objective, correct relay coordination setting is important to prevent the system from suffering catastrophic effects. These days, the consumer is enforcing raising performance demands by reducing operational and maintenance costs. At the same moment, improvement of the consistency and quality of supply is required. The cumulative fault current at each bus in the network needs to be determined to achieve the most effective relay coordination. This will be along with the calculation of relay settings to get the Time Setting Multiplier (TMS) value. The differential time graph of the relay grading curves will be plotted based on the value of size of CT, current setting, relay characteristic and TMS. This is due to the small margin inherited from the upper-stream utilities, a thorough analysis needs to be performed to achieve the strongest relay communication to a ring delivery network. This research report includes of reviewing of new ones of OCEF relay coordination setting in a ring distribution system, calculations on fault current, and suggestion on improvement of the relay coordination setting using directional relay and non-directional relay. A software to use for OCEF relay simulation of a distribution system was developed by writer using Microsoft Excel. It consists of fault current calculation, relay setting calculations and graphical plot of the relay grading curves. The proposed improvement of the relay coordination environment using directional relay and non-directional relay would provide a better method of distribution in terms of reliability and maintainability.
format Thesis
id oai:studentsrepo.um.edu.my:12108
institution Universiti Malaya
publishDate 2020
record_format eprints
spelling oai:studentsrepo.um.edu.my:121082021-03-07T17:15:58Z Analysis of protection system setting in 11KV distribution system / Ammar Alamshah Ammar, Alamshah TK Electrical engineering. Electronics Nuclear engineering One of the fundamental protections used in electrical network power system is Overcurrent and Earth Fault (OCEF) protection. They have to be both sensitive and quick in minimizing the electrodynamic and thermal stress imposed on the equipment during the fault time interval. It is utmost important for the relays to be capable of removing only the faulty section while keep up the flexibly to solid areas in the system. In order to achieve this objective, correct relay coordination setting is important to prevent the system from suffering catastrophic effects. These days, the consumer is enforcing raising performance demands by reducing operational and maintenance costs. At the same moment, improvement of the consistency and quality of supply is required. The cumulative fault current at each bus in the network needs to be determined to achieve the most effective relay coordination. This will be along with the calculation of relay settings to get the Time Setting Multiplier (TMS) value. The differential time graph of the relay grading curves will be plotted based on the value of size of CT, current setting, relay characteristic and TMS. This is due to the small margin inherited from the upper-stream utilities, a thorough analysis needs to be performed to achieve the strongest relay communication to a ring delivery network. This research report includes of reviewing of new ones of OCEF relay coordination setting in a ring distribution system, calculations on fault current, and suggestion on improvement of the relay coordination setting using directional relay and non-directional relay. A software to use for OCEF relay simulation of a distribution system was developed by writer using Microsoft Excel. It consists of fault current calculation, relay setting calculations and graphical plot of the relay grading curves. The proposed improvement of the relay coordination environment using directional relay and non-directional relay would provide a better method of distribution in terms of reliability and maintainability. 2020-08 Thesis NonPeerReviewed application/pdf http://studentsrepo.um.edu.my/12108/1/Ammar_Alamshah.jpg application/pdf http://studentsrepo.um.edu.my/12108/8/ammar.pdf Ammar, Alamshah (2020) Analysis of protection system setting in 11KV distribution system / Ammar Alamshah. Masters thesis, University of Malaya. http://studentsrepo.um.edu.my/12108/
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Ammar, Alamshah
Analysis of protection system setting in 11KV distribution system / Ammar Alamshah
title Analysis of protection system setting in 11KV distribution system / Ammar Alamshah
title_full Analysis of protection system setting in 11KV distribution system / Ammar Alamshah
title_fullStr Analysis of protection system setting in 11KV distribution system / Ammar Alamshah
title_full_unstemmed Analysis of protection system setting in 11KV distribution system / Ammar Alamshah
title_short Analysis of protection system setting in 11KV distribution system / Ammar Alamshah
title_sort analysis of protection system setting in 11kv distribution system ammar alamshah
topic TK Electrical engineering. Electronics Nuclear engineering
url-record http://studentsrepo.um.edu.my/12108/
work_keys_str_mv AT ammaralamshah analysisofprotectionsystemsettingin11kvdistributionsystemammaralamshah