Entiometric membrane sensor for determination of glutamate based on [4](1)(2,3-diazabuta-l,3- diene) ferrocenophane

Bibliographic Details
Main Author: Norhafizah Bakeman
Format: Thesis
Language:English
Published: 2014
Subjects:
Online Access:https://ir.upsi.edu.my/detailsg.php?det=1072
Abstract Abstract here
_version_ 1855625598445027328
author Norhafizah Bakeman
author_facet Norhafizah Bakeman
author_sort Norhafizah Bakeman
description
format Thesis
id upsi-1072
institution Universiti Pendidikan Sultan Idris
language English
publishDate 2014
record_format sWADAH
record_pdf Restricted
spelling upsi-10722020-02-27 Entiometric membrane sensor for determination of glutamate based on [4](1)(2,3-diazabuta-l,3- diene) ferrocenophane 2014 Norhafizah Bakeman QC Physics A potentiometric membrane sensor has been developed and optimized based on [4](l)(2,3-diazabuta-l,3-diene)ferrocenophane as an ionophore for high selective determination of glutamate. The best performance was shown by a membrane with composition ratio of [4](l)(2,3-diazabuta-l,3-diene)ferrocenophane (ionophore): PVC (binder): TEHP (plasticizer) at 9: 36: 55 (% w/w). The sensor works well in a linear range of 1.0 x 105 to 1.0 x 10"1 M glutamate with a Nemstian slope of 57.61.0 mV/decade and its detection limit is 7.95 x 10'6 M. The sensor shows working range within pH 6-10 at temperature 25.01 C and stable for a period of 3 months without any divergence in potentials with response time equal or less than 30 seconds. The selectivity coefficient values determined by mixed solution method, indicate a good selectivity for glutamate over a wide variety of other tested anions. 2014 thesis https://ir.upsi.edu.my/detailsg.php?det=1072 https://ir.upsi.edu.my/detailsg.php?det=1072 text eng N/A openAccess Masters Universiti Pendidikan Sultan Idris Fakulti Sains dan Matematik N/A
spellingShingle QC Physics
Norhafizah Bakeman
Entiometric membrane sensor for determination of glutamate based on [4](1)(2,3-diazabuta-l,3- diene) ferrocenophane
thesis_level Master
title Entiometric membrane sensor for determination of glutamate based on [4](1)(2,3-diazabuta-l,3- diene) ferrocenophane
title_full Entiometric membrane sensor for determination of glutamate based on [4](1)(2,3-diazabuta-l,3- diene) ferrocenophane
title_fullStr Entiometric membrane sensor for determination of glutamate based on [4](1)(2,3-diazabuta-l,3- diene) ferrocenophane
title_full_unstemmed Entiometric membrane sensor for determination of glutamate based on [4](1)(2,3-diazabuta-l,3- diene) ferrocenophane
title_short Entiometric membrane sensor for determination of glutamate based on [4](1)(2,3-diazabuta-l,3- diene) ferrocenophane
title_sort entiometric membrane sensor for determination of glutamate based on 4 1 2 3 diazabuta l 3 diene ferrocenophane
topic QC Physics
url https://ir.upsi.edu.my/detailsg.php?det=1072
work_keys_str_mv AT norhafizahbakeman entiometricmembranesensorfordeterminationofglutamatebasedon4123diazabutal3dieneferrocenophane