Comparison of varus malalignment in unstable extracapsular proximal femur fracture between proximal femoral nail antirotation (PFNA) and proximal femoral locking plate (PFLCP) : a retrospective study

Unstable fractures of proximal femur of the pertrochanteric and subtrochanteric region are challenging injuries due to the high loads transmission across the affected part of the bone to the hip joint. The selection of the implants remained controversial but many studies favouring intramedullary imp...

Full description

Bibliographic Details
Main Author: Lee, Mohammad Faizal Nikman
Format: Thesis
Language:English
Published: 2017
Subjects:
Online Access:http://eprints.usm.my/43075/
Abstract Abstract here
_version_ 1855632179423346688
author Lee, Mohammad Faizal Nikman
author_facet Lee, Mohammad Faizal Nikman
author_sort Lee, Mohammad Faizal Nikman
description Unstable fractures of proximal femur of the pertrochanteric and subtrochanteric region are challenging injuries due to the high loads transmission across the affected part of the bone to the hip joint. The selection of the implants remained controversial but many studies favouring intramedullary implants for fractures’ fixation. The nature of the bone with strong muscular action with high compressive forces acting medially are responsible for intraoperative and postoperative complications and difficulties. Varus malalignment is one of the commonest complication found in proximal femur fractures. This study was done to evaluate the incidence of varus malalignment in unstable extracapsular proximal femur fracture. METHODS: 60 patients with closed unstable fracture of proximal femur involving pertrochanteric and subtrochanteric region were subjected into 2 groups of fixation and retrospectively evaluated. 30 patients each for proximal femoral nail antirotation (PFNA) and proximal femoral locking plate (PFLCP) group were operated. Incidence of varus malalignment immediately post operation, quality of fracture’s reduction immediately post operation and implant’s sustainability of fracture’s reduction at 6 months post operation were analyzed for both groups. RESULTS: Immediately after fracture’s fixation, incidence of varus malalignment was higher in PFLCP group (23.3%) compared to PFNA group (13.3%). However the quality of fracture’s reduction immediately post operation and implant’s sustainability of fracture’s reduction at 6 months between both implants were not statistically significant. CONCLUSIONS: PFLCP offered comparable result as PFNA for osteosysnthesis of unstable extracapsular proximal femur fracture in term of varus malalignment on immediate and 6 months post operation.
first_indexed 2025-10-17T08:20:53Z
format Thesis
id usm-43075
institution Universiti Sains Malaysia
language English
last_indexed 2025-10-17T08:20:53Z
publishDate 2017
record_format EPrints
record_pdf Restricted
spelling usm-430752019-04-12T05:25:07Z http://eprints.usm.my/43075/ Comparison of varus malalignment in unstable extracapsular proximal femur fracture between proximal femoral nail antirotation (PFNA) and proximal femoral locking plate (PFLCP) : a retrospective study Lee, Mohammad Faizal Nikman RC31-1245 Internal medicine Unstable fractures of proximal femur of the pertrochanteric and subtrochanteric region are challenging injuries due to the high loads transmission across the affected part of the bone to the hip joint. The selection of the implants remained controversial but many studies favouring intramedullary implants for fractures’ fixation. The nature of the bone with strong muscular action with high compressive forces acting medially are responsible for intraoperative and postoperative complications and difficulties. Varus malalignment is one of the commonest complication found in proximal femur fractures. This study was done to evaluate the incidence of varus malalignment in unstable extracapsular proximal femur fracture. METHODS: 60 patients with closed unstable fracture of proximal femur involving pertrochanteric and subtrochanteric region were subjected into 2 groups of fixation and retrospectively evaluated. 30 patients each for proximal femoral nail antirotation (PFNA) and proximal femoral locking plate (PFLCP) group were operated. Incidence of varus malalignment immediately post operation, quality of fracture’s reduction immediately post operation and implant’s sustainability of fracture’s reduction at 6 months post operation were analyzed for both groups. RESULTS: Immediately after fracture’s fixation, incidence of varus malalignment was higher in PFLCP group (23.3%) compared to PFNA group (13.3%). However the quality of fracture’s reduction immediately post operation and implant’s sustainability of fracture’s reduction at 6 months between both implants were not statistically significant. CONCLUSIONS: PFLCP offered comparable result as PFNA for osteosysnthesis of unstable extracapsular proximal femur fracture in term of varus malalignment on immediate and 6 months post operation. 2017 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/43075/1/Dr._Mohammad_Faizal_Nikman_Lee-24_pages.pdf Lee, Mohammad Faizal Nikman (2017) Comparison of varus malalignment in unstable extracapsular proximal femur fracture between proximal femoral nail antirotation (PFNA) and proximal femoral locking plate (PFLCP) : a retrospective study. Masters thesis, Universiti Sains Malaysia.
spellingShingle RC31-1245 Internal medicine
Lee, Mohammad Faizal Nikman
Comparison of varus malalignment in unstable extracapsular proximal femur fracture between proximal femoral nail antirotation (PFNA) and proximal femoral locking plate (PFLCP) : a retrospective study
thesis_level Master
title Comparison of varus malalignment in unstable extracapsular proximal femur fracture between proximal femoral nail antirotation (PFNA) and proximal femoral locking plate (PFLCP) : a retrospective study
title_full Comparison of varus malalignment in unstable extracapsular proximal femur fracture between proximal femoral nail antirotation (PFNA) and proximal femoral locking plate (PFLCP) : a retrospective study
title_fullStr Comparison of varus malalignment in unstable extracapsular proximal femur fracture between proximal femoral nail antirotation (PFNA) and proximal femoral locking plate (PFLCP) : a retrospective study
title_full_unstemmed Comparison of varus malalignment in unstable extracapsular proximal femur fracture between proximal femoral nail antirotation (PFNA) and proximal femoral locking plate (PFLCP) : a retrospective study
title_short Comparison of varus malalignment in unstable extracapsular proximal femur fracture between proximal femoral nail antirotation (PFNA) and proximal femoral locking plate (PFLCP) : a retrospective study
title_sort comparison of varus malalignment in unstable extracapsular proximal femur fracture between proximal femoral nail antirotation pfna and proximal femoral locking plate pflcp a retrospective study
topic RC31-1245 Internal medicine
url http://eprints.usm.my/43075/
work_keys_str_mv AT leemohammadfaizalnikman comparisonofvarusmalalignmentinunstableextracapsularproximalfemurfracturebetweenproximalfemoralnailantirotationpfnaandproximalfemorallockingplatepflcparetrospectivestudy