Exposure rate in mobile c-arm fluoroscopy and radioiodine therapy

This study is done to measure the exposure rate from mobile c-arm fluoroscopy and patients undergo radioiodine therapy. The measurement of exposure rate from mobile c-arm fluoroscopy was carried out using survey meter model 451 B, and also lead apron with 0.5 mm lead equivalence thickness. The ex...

詳細記述

書誌詳細
第一著者: Shalleh, Norzulaili Md
フォーマット: 学位論文
言語:英語
出版事項: 2004
主題:
オンライン・アクセス:http://eprints.usm.my/46336/
_version_ 1846217048404787200
author Shalleh, Norzulaili Md
author_facet Shalleh, Norzulaili Md
author_sort Shalleh, Norzulaili Md
description This study is done to measure the exposure rate from mobile c-arm fluoroscopy and patients undergo radioiodine therapy. The measurement of exposure rate from mobile c-arm fluoroscopy was carried out using survey meter model 451 B, and also lead apron with 0.5 mm lead equivalence thickness. The exposure time, distance, shielding material and value of kVp and mAs were considered. This study was done by varied the exposure time of mobile c-arm fluoroscopy while the value of kVp was remaining constant. This was done to see the effect of exposure time to the exposure rate. From this study, we found that the exposure rate was increased exponentially with exposure time. This study also done by varied the distance of survey meter from mobile c-arm fluoroscopy. This was done to see the effect of distance to the exposure rate. From this study, we found that the exposure rate decreased for about 30% when the distance increased by 1 0 em. Besides that, this study was also done; by covering the survey meter with lead apron with 0.5 mm lead equivalence thickness. This was done to see the effect of shielding to the exposure rate. We found that the exposure rate decreased for more than 90o/o when the lead apron was used. We also measured the exposure rate from patients undergo radioiodine therapy. This study was done after the patients had drunk the radioiodine solution for 30 minutes. This study also used survey meter model 451 B to measure the exposure rate from various distance. From this study, we found that the exposure rate from radioiodine therapy patients decreased exponentially with increasing distance. As conclusion, we can say that the exposure rate from mobile c-arm fluoroscopy and patients undergo radioiodine therapy, can be minimized by increasing distance, decreasing exposure time, and also by using shielding materials.
first_indexed 2025-10-17T08:29:41Z
format Thesis
id usm-46336
institution Universiti Sains Malaysia
language English
last_indexed 2025-10-17T08:29:41Z
publishDate 2004
record_format eprints
spelling usm-463362020-02-26T03:28:22Z http://eprints.usm.my/46336/ Exposure rate in mobile c-arm fluoroscopy and radioiodine therapy Shalleh, Norzulaili Md R Medicine (General) This study is done to measure the exposure rate from mobile c-arm fluoroscopy and patients undergo radioiodine therapy. The measurement of exposure rate from mobile c-arm fluoroscopy was carried out using survey meter model 451 B, and also lead apron with 0.5 mm lead equivalence thickness. The exposure time, distance, shielding material and value of kVp and mAs were considered. This study was done by varied the exposure time of mobile c-arm fluoroscopy while the value of kVp was remaining constant. This was done to see the effect of exposure time to the exposure rate. From this study, we found that the exposure rate was increased exponentially with exposure time. This study also done by varied the distance of survey meter from mobile c-arm fluoroscopy. This was done to see the effect of distance to the exposure rate. From this study, we found that the exposure rate decreased for about 30% when the distance increased by 1 0 em. Besides that, this study was also done; by covering the survey meter with lead apron with 0.5 mm lead equivalence thickness. This was done to see the effect of shielding to the exposure rate. We found that the exposure rate decreased for more than 90o/o when the lead apron was used. We also measured the exposure rate from patients undergo radioiodine therapy. This study was done after the patients had drunk the radioiodine solution for 30 minutes. This study also used survey meter model 451 B to measure the exposure rate from various distance. From this study, we found that the exposure rate from radioiodine therapy patients decreased exponentially with increasing distance. As conclusion, we can say that the exposure rate from mobile c-arm fluoroscopy and patients undergo radioiodine therapy, can be minimized by increasing distance, decreasing exposure time, and also by using shielding materials. 2004 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/46336/1/LI...Norzulaili%20Binti%20Md.Shalleh...2004...-24%20pages.pdf Shalleh, Norzulaili Md (2004) Exposure rate in mobile c-arm fluoroscopy and radioiodine therapy. Other thesis, Universiti Sains Malaysia.
spellingShingle R Medicine (General)
Shalleh, Norzulaili Md
Exposure rate in mobile c-arm fluoroscopy and radioiodine therapy
title Exposure rate in mobile c-arm fluoroscopy and radioiodine therapy
title_full Exposure rate in mobile c-arm fluoroscopy and radioiodine therapy
title_fullStr Exposure rate in mobile c-arm fluoroscopy and radioiodine therapy
title_full_unstemmed Exposure rate in mobile c-arm fluoroscopy and radioiodine therapy
title_short Exposure rate in mobile c-arm fluoroscopy and radioiodine therapy
title_sort exposure rate in mobile c arm fluoroscopy and radioiodine therapy
topic R Medicine (General)
url http://eprints.usm.my/46336/
work_keys_str_mv AT shallehnorzulailimd exposurerateinmobilecarmfluoroscopyandradioiodinetherapy