A comparative study between glidescope® videolaryngoscope and direct laryngoscope using modified rapid sequence induction on haemodynamic parameters during intubation

There are different techniques of intubation of trachea apart from standard direct laryngoscopy. Every technique produces sympathetic response in varying degrees. Glidescope® videolaryngoscope, is a relatively new intubating device to improve the glottic view without aligning the three airway axe...

पूर्ण विवरण

ग्रंथसूची विवरण
मुख्य लेखक: Azarina, Zakaria
स्वरूप: थीसिस
भाषा:अंग्रेज़ी
प्रकाशित: 2008
विषय:
ऑनलाइन पहुंच:http://eprints.usm.my/53568/
_version_ 1846217737896984576
author Azarina, Zakaria
author_facet Azarina, Zakaria
author_sort Azarina, Zakaria
description There are different techniques of intubation of trachea apart from standard direct laryngoscopy. Every technique produces sympathetic response in varying degrees. Glidescope® videolaryngoscope, is a relatively new intubating device to improve the glottic view without aligning the three airway axes as done in standard direct laryngoscopy and is said to cause less airway manipulations. Our study is to see if Glidescope® videolaryngoscopic technique would alter the sympathetic response as normally seen in standard laryngoscopy. To assess haemodynamic responses between direct laryngoscopy and Glidescope® videolaryngoscope during laryngoscopy and intubation. This is a prospective randomized study involving 64 ASA I and II patients divided into 2 groups (n=32); direct laryngoscopy and Glidescope® group. Anaesthesia was induced with intravenous injection of fentanyl 1.51Jg/kg, propofol 2mg/kg and rocuronium 1 mg/kg. Orotracheal intubation was started at least 1 minute after rocuronium injection. Noninvasive blood pressure (BP), heart rate and oxygen saturation were recorded before (baseline value) and immediately after induction, during intubation, and for 5 minutes later, at one-minute intervals. Intubation time was significantly longer in the Glidescope® group (mean 35.67±9.59sec) when compared to direct laryngoscopy group (mean 20.13±5.03sec), p<0.001. In the Glidescope® group, the systolic blood pressure, diastolic blood pressure, mean arterial pressure and heart rate were significantly higher than the direct laryngoscopy group. The increase in heart rate in Glidescope® group took more than 5 minutes to return to baseline values compared to only 3 minutes in direct laryngoscopy group. Direct laryngoscopy showed better haemodynamic parameters of mean SBP, DBP, MAP and heart rate compared to Glidescope® videolaryngoscope. However, the increase in haemodynamic parameters in the Glidescope® group was not more than 20% of baseline values and this was still acceptable to our routine standard anaesthetic management.
first_indexed 2025-10-17T08:40:39Z
format Thesis
id usm-53568
institution Universiti Sains Malaysia
language English
last_indexed 2025-10-17T08:40:39Z
publishDate 2008
record_format eprints
spelling usm-535682022-07-25T03:05:32Z http://eprints.usm.my/53568/ A comparative study between glidescope® videolaryngoscope and direct laryngoscope using modified rapid sequence induction on haemodynamic parameters during intubation Azarina, Zakaria R Medicine (General) There are different techniques of intubation of trachea apart from standard direct laryngoscopy. Every technique produces sympathetic response in varying degrees. Glidescope® videolaryngoscope, is a relatively new intubating device to improve the glottic view without aligning the three airway axes as done in standard direct laryngoscopy and is said to cause less airway manipulations. Our study is to see if Glidescope® videolaryngoscopic technique would alter the sympathetic response as normally seen in standard laryngoscopy. To assess haemodynamic responses between direct laryngoscopy and Glidescope® videolaryngoscope during laryngoscopy and intubation. This is a prospective randomized study involving 64 ASA I and II patients divided into 2 groups (n=32); direct laryngoscopy and Glidescope® group. Anaesthesia was induced with intravenous injection of fentanyl 1.51Jg/kg, propofol 2mg/kg and rocuronium 1 mg/kg. Orotracheal intubation was started at least 1 minute after rocuronium injection. Noninvasive blood pressure (BP), heart rate and oxygen saturation were recorded before (baseline value) and immediately after induction, during intubation, and for 5 minutes later, at one-minute intervals. Intubation time was significantly longer in the Glidescope® group (mean 35.67±9.59sec) when compared to direct laryngoscopy group (mean 20.13±5.03sec), p<0.001. In the Glidescope® group, the systolic blood pressure, diastolic blood pressure, mean arterial pressure and heart rate were significantly higher than the direct laryngoscopy group. The increase in heart rate in Glidescope® group took more than 5 minutes to return to baseline values compared to only 3 minutes in direct laryngoscopy group. Direct laryngoscopy showed better haemodynamic parameters of mean SBP, DBP, MAP and heart rate compared to Glidescope® videolaryngoscope. However, the increase in haemodynamic parameters in the Glidescope® group was not more than 20% of baseline values and this was still acceptable to our routine standard anaesthetic management. 2008 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/53568/1/DR.AZARINA%20BINTI%20ZAKARIA%20-%2024%20pages.pdf Azarina, Zakaria (2008) A comparative study between glidescope® videolaryngoscope and direct laryngoscope using modified rapid sequence induction on haemodynamic parameters during intubation. Masters thesis, Pusat Pengajian Sains Perubatan.
spellingShingle R Medicine (General)
Azarina, Zakaria
A comparative study between glidescope® videolaryngoscope and direct laryngoscope using modified rapid sequence induction on haemodynamic parameters during intubation
title A comparative study between glidescope® videolaryngoscope and direct laryngoscope using modified rapid sequence induction on haemodynamic parameters during intubation
title_full A comparative study between glidescope® videolaryngoscope and direct laryngoscope using modified rapid sequence induction on haemodynamic parameters during intubation
title_fullStr A comparative study between glidescope® videolaryngoscope and direct laryngoscope using modified rapid sequence induction on haemodynamic parameters during intubation
title_full_unstemmed A comparative study between glidescope® videolaryngoscope and direct laryngoscope using modified rapid sequence induction on haemodynamic parameters during intubation
title_short A comparative study between glidescope® videolaryngoscope and direct laryngoscope using modified rapid sequence induction on haemodynamic parameters during intubation
title_sort comparative study between glidescope r videolaryngoscope and direct laryngoscope using modified rapid sequence induction on haemodynamic parameters during intubation
topic R Medicine (General)
url http://eprints.usm.my/53568/
work_keys_str_mv AT azarinazakaria acomparativestudybetweenglidescopevideolaryngoscopeanddirectlaryngoscopeusingmodifiedrapidsequenceinductiononhaemodynamicparametersduringintubation
AT azarinazakaria comparativestudybetweenglidescopevideolaryngoscopeanddirectlaryngoscopeusingmodifiedrapidsequenceinductiononhaemodynamicparametersduringintubation