Reduction Of Membrane Fouling Using Helical Baffles For Crossflow Microfiltration

The objectives of this research is investigate the use of helical baffles as a hydrodynamic for reducing membrane fouling and enhancing the flux. Experiments were conducted using ceramic, tubular membranes and using Ti02 suspensions and Bakers yeast solutions as the feed. The optimum configuration...

詳細記述

書誌詳細
第一著者: Mariadas, Anthony
フォーマット: 学位論文
言語:英語
出版事項: 2003
主題:
オンライン・アクセス:http://eprints.usm.my/61876/
_version_ 1846218442014720000
author Mariadas, Anthony
author_facet Mariadas, Anthony
author_sort Mariadas, Anthony
description The objectives of this research is investigate the use of helical baffles as a hydrodynamic for reducing membrane fouling and enhancing the flux. Experiments were conducted using ceramic, tubular membranes and using Ti02 suspensions and Bakers yeast solutions as the feed. The optimum configurations of helical baffles in respect to the geometry were explored. The effect of operating parameters such as different Transmembrane pressure, different feed concentrations, different shape of membrane inner surface, long hour experiments and the effect of different types of feed on flux were also conducted.
first_indexed 2025-10-17T08:51:50Z
format Thesis
id usm-61876
institution Universiti Sains Malaysia
language English
last_indexed 2025-10-17T08:51:50Z
publishDate 2003
record_format eprints
spelling usm-618762025-02-24T03:35:33Z http://eprints.usm.my/61876/ Reduction Of Membrane Fouling Using Helical Baffles For Crossflow Microfiltration Mariadas, Anthony TP1-1185 Chemical technology The objectives of this research is investigate the use of helical baffles as a hydrodynamic for reducing membrane fouling and enhancing the flux. Experiments were conducted using ceramic, tubular membranes and using Ti02 suspensions and Bakers yeast solutions as the feed. The optimum configurations of helical baffles in respect to the geometry were explored. The effect of operating parameters such as different Transmembrane pressure, different feed concentrations, different shape of membrane inner surface, long hour experiments and the effect of different types of feed on flux were also conducted. 2003-04 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/61876/1/Pages%20from%20Anthony%20Mariadas.pdf Mariadas, Anthony (2003) Reduction Of Membrane Fouling Using Helical Baffles For Crossflow Microfiltration. Masters thesis, Universiti Sains Malaysia.
spellingShingle TP1-1185 Chemical technology
Mariadas, Anthony
Reduction Of Membrane Fouling Using Helical Baffles For Crossflow Microfiltration
title Reduction Of Membrane Fouling Using Helical Baffles For Crossflow Microfiltration
title_full Reduction Of Membrane Fouling Using Helical Baffles For Crossflow Microfiltration
title_fullStr Reduction Of Membrane Fouling Using Helical Baffles For Crossflow Microfiltration
title_full_unstemmed Reduction Of Membrane Fouling Using Helical Baffles For Crossflow Microfiltration
title_short Reduction Of Membrane Fouling Using Helical Baffles For Crossflow Microfiltration
title_sort reduction of membrane fouling using helical baffles for crossflow microfiltration
topic TP1-1185 Chemical technology
url http://eprints.usm.my/61876/
work_keys_str_mv AT mariadasanthony reductionofmembranefoulingusinghelicalbafflesforcrossflowmicrofiltration