A randomized control trial: insertion of peripherally inserted central catheter (picc) in neonates; mathematical formula versus direct measurement

Introduction Peripherally inserted central catheters (PICC) is commonly used in preterm infants. However, many studies have shown a high need for adjustment of their position after insertion. The aim of this study was to test a new method to estimate the ideal catheter depth for cubital PICC insert...

Full description

Bibliographic Details
Main Author: Jusili, Syamila Huda
Format: Thesis
Language:English
Published: 2023
Subjects:
Online Access:http://eprints.usm.my/62769/
_version_ 1846218600510128128
author Jusili, Syamila Huda
author_facet Jusili, Syamila Huda
author_sort Jusili, Syamila Huda
description Introduction Peripherally inserted central catheters (PICC) is commonly used in preterm infants. However, many studies have shown a high need for adjustment of their position after insertion. The aim of this study was to test a new method to estimate the ideal catheter depth for cubital PICC insertion in preterm infants. Methods A multi-center randomized, controlled trial was conducted, comparing direct measurement from insertion site to sternal notch (control group) versus a formula based on the length of the infant (intervention group) to estimate the ideal depth of cubital PICC in preterm infants with a birth of less than 1.5kg. The primary outcome was the rate of correctly placed PICCs. Catheter related complications were also monitored. Results There was no difference in baseline characteristics between the intervention group and the control group except for a significant lower birth weight in the intervention group. There was no significant difference in correct placement between the intervention and the control groups (6 out of 25 or 24% vs 10 out of 27 or 37% respectively, p=0.309). There was also no significant difference in complication rates between the two groups. Discussion and conclusion This study did not show benefits of using an alternative formula for estimation of catheter depth for cubital PICC insertion in preterm infants. As in previous studies the rate of correct initial placement was low and there is definitely a need for studies to identify better ways to estimate the depth of PICC insertion for preterm infants.
first_indexed 2025-10-17T08:54:21Z
format Thesis
id usm-62769
institution Universiti Sains Malaysia
language English
last_indexed 2025-10-17T08:54:21Z
publishDate 2023
record_format eprints
spelling usm-627692025-08-18T07:55:20Z http://eprints.usm.my/62769/ A randomized control trial: insertion of peripherally inserted central catheter (picc) in neonates; mathematical formula versus direct measurement Jusili, Syamila Huda R Medicine RJ Pediatrics Introduction Peripherally inserted central catheters (PICC) is commonly used in preterm infants. However, many studies have shown a high need for adjustment of their position after insertion. The aim of this study was to test a new method to estimate the ideal catheter depth for cubital PICC insertion in preterm infants. Methods A multi-center randomized, controlled trial was conducted, comparing direct measurement from insertion site to sternal notch (control group) versus a formula based on the length of the infant (intervention group) to estimate the ideal depth of cubital PICC in preterm infants with a birth of less than 1.5kg. The primary outcome was the rate of correctly placed PICCs. Catheter related complications were also monitored. Results There was no difference in baseline characteristics between the intervention group and the control group except for a significant lower birth weight in the intervention group. There was no significant difference in correct placement between the intervention and the control groups (6 out of 25 or 24% vs 10 out of 27 or 37% respectively, p=0.309). There was also no significant difference in complication rates between the two groups. Discussion and conclusion This study did not show benefits of using an alternative formula for estimation of catheter depth for cubital PICC insertion in preterm infants. As in previous studies the rate of correct initial placement was low and there is definitely a need for studies to identify better ways to estimate the depth of PICC insertion for preterm infants. 2023-02 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/62769/1/Syamila%20Huda%20Jusili%20-%20E.pdf Jusili, Syamila Huda (2023) A randomized control trial: insertion of peripherally inserted central catheter (picc) in neonates; mathematical formula versus direct measurement. Masters thesis, Universiti Sains Malaysia.
spellingShingle R Medicine
RJ Pediatrics
Jusili, Syamila Huda
A randomized control trial: insertion of peripherally inserted central catheter (picc) in neonates; mathematical formula versus direct measurement
title A randomized control trial: insertion of peripherally inserted central catheter (picc) in neonates; mathematical formula versus direct measurement
title_full A randomized control trial: insertion of peripherally inserted central catheter (picc) in neonates; mathematical formula versus direct measurement
title_fullStr A randomized control trial: insertion of peripherally inserted central catheter (picc) in neonates; mathematical formula versus direct measurement
title_full_unstemmed A randomized control trial: insertion of peripherally inserted central catheter (picc) in neonates; mathematical formula versus direct measurement
title_short A randomized control trial: insertion of peripherally inserted central catheter (picc) in neonates; mathematical formula versus direct measurement
title_sort randomized control trial insertion of peripherally inserted central catheter picc in neonates mathematical formula versus direct measurement
topic R Medicine
RJ Pediatrics
url http://eprints.usm.my/62769/
work_keys_str_mv AT jusilisyamilahuda arandomizedcontroltrialinsertionofperipherallyinsertedcentralcatheterpiccinneonatesmathematicalformulaversusdirectmeasurement
AT jusilisyamilahuda randomizedcontroltrialinsertionofperipherallyinsertedcentralcatheterpiccinneonatesmathematicalformulaversusdirectmeasurement