Analysis Of Energy Usage In Pusat Persatuan Pelajar

Energy analysis is important in resolving energy consuming modality,due to observing how the energy utilized has shifted with time in the building and how the arrangement elements interrelate with each other.In this case study,a preliminary energy audit is done on the existing indoor parameters.The...

詳細記述

書誌詳細
第一著者: Najem, Ibrahim Hamad Mohamed
フォーマット: 学位論文
言語:英語
英語
出版事項: 2018
主題:
オンライン・アクセス:http://eprints.utem.edu.my/id/eprint/21454/
http://libraryopac.utem.edu.my/webopac20/Record/0000107862
Abstract Abstract here
_version_ 1855619682558541824
author Najem, Ibrahim Hamad Mohamed
author_facet Najem, Ibrahim Hamad Mohamed
author_sort Najem, Ibrahim Hamad Mohamed
description Energy analysis is important in resolving energy consuming modality,due to observing how the energy utilized has shifted with time in the building and how the arrangement elements interrelate with each other.In this case study,a preliminary energy audit is done on the existing indoor parameters.The study was conducted at Pusat Persatuan Pelajar (PPP),Universiti Teknikal Malaysia (UTeM).The project is aimed at comparing the lighting index between PPP building and the current Malaysian standard (Malaysian Standard 1525:2014).This undertaking is also aimed at evaluating and analyzing energy used in the PPP building.To calculate the electricity consumption and lighting,physical indoor data was collected through a clamp meter and lux meter on three floors in the PPP building.The air-conditioning system in the selected rooms was left for one hour before starting the measurements.The lighting data was collected between 10 am to 12 pm and again 2 pm to 4 pm with a gap of 20 minutes for each reading.The results show indicated that the energy consumption of the air-conditioning system was 11157.76 kWh and cost-ing RM 4072.58 per month.From lighting system analysis, the energy consumption was 6600.16 kWh and costing RM 2409.05 per month.The project also studies the current lighting system and a proposed energy retrofit to save energy usage.After proposing ret-rofit plan,the energy consumption can be saved 18931 kWh per month and RM 1105.57 per month.The difference of power consumption for a month March in 2017 between the measurements and electricity bill analysis is about 5%.Since the difference is too small, therefore,it can be concluded that the obtained the Building Energy Index (BEI) value in the project is reliable.Most of the lighting levels in every audited zone exceed Malaysian Standard MS 1525:2014.In addition,the Building Energy Index (BEI) for all the building is 233.67kWh/m²/year and for each level is 77.89 kWh/m²/year.The best BEI exercise and recommended by Malaysian Standard is 135kWh/m²/year.
format Thesis
id utem-21454
institution Universiti Teknikal Malaysia Melaka
language English
English
publishDate 2018
record_format EPrints
record_pdf Restricted
spelling utem-214542022-02-07T14:45:46Z http://eprints.utem.edu.my/id/eprint/21454/ Analysis Of Energy Usage In Pusat Persatuan Pelajar Najem, Ibrahim Hamad Mohamed T Technology (General) TJ Mechanical engineering and machinery Energy analysis is important in resolving energy consuming modality,due to observing how the energy utilized has shifted with time in the building and how the arrangement elements interrelate with each other.In this case study,a preliminary energy audit is done on the existing indoor parameters.The study was conducted at Pusat Persatuan Pelajar (PPP),Universiti Teknikal Malaysia (UTeM).The project is aimed at comparing the lighting index between PPP building and the current Malaysian standard (Malaysian Standard 1525:2014).This undertaking is also aimed at evaluating and analyzing energy used in the PPP building.To calculate the electricity consumption and lighting,physical indoor data was collected through a clamp meter and lux meter on three floors in the PPP building.The air-conditioning system in the selected rooms was left for one hour before starting the measurements.The lighting data was collected between 10 am to 12 pm and again 2 pm to 4 pm with a gap of 20 minutes for each reading.The results show indicated that the energy consumption of the air-conditioning system was 11157.76 kWh and cost-ing RM 4072.58 per month.From lighting system analysis, the energy consumption was 6600.16 kWh and costing RM 2409.05 per month.The project also studies the current lighting system and a proposed energy retrofit to save energy usage.After proposing ret-rofit plan,the energy consumption can be saved 18931 kWh per month and RM 1105.57 per month.The difference of power consumption for a month March in 2017 between the measurements and electricity bill analysis is about 5%.Since the difference is too small, therefore,it can be concluded that the obtained the Building Energy Index (BEI) value in the project is reliable.Most of the lighting levels in every audited zone exceed Malaysian Standard MS 1525:2014.In addition,the Building Energy Index (BEI) for all the building is 233.67kWh/m²/year and for each level is 77.89 kWh/m²/year.The best BEI exercise and recommended by Malaysian Standard is 135kWh/m²/year. 2018 Thesis NonPeerReviewed text en http://eprints.utem.edu.my/id/eprint/21454/1/Analysis%20Of%20Energy%20Usage%20In%20Pusat%20Persatuan%20Pelajar.pdf text en http://eprints.utem.edu.my/id/eprint/21454/2/Analysis%20Of%20Energy%20Usage%20In%20Pusat%20Persatuan%20Pelajar.pdf Najem, Ibrahim Hamad Mohamed (2018) Analysis Of Energy Usage In Pusat Persatuan Pelajar. Masters thesis, UTeM. http://libraryopac.utem.edu.my/webopac20/Record/0000107862
spellingShingle T Technology (General)
TJ Mechanical engineering and machinery
Najem, Ibrahim Hamad Mohamed
Analysis Of Energy Usage In Pusat Persatuan Pelajar
thesis_level Master
title Analysis Of Energy Usage In Pusat Persatuan Pelajar
title_full Analysis Of Energy Usage In Pusat Persatuan Pelajar
title_fullStr Analysis Of Energy Usage In Pusat Persatuan Pelajar
title_full_unstemmed Analysis Of Energy Usage In Pusat Persatuan Pelajar
title_short Analysis Of Energy Usage In Pusat Persatuan Pelajar
title_sort analysis of energy usage in pusat persatuan pelajar
topic T Technology (General)
TJ Mechanical engineering and machinery
url http://eprints.utem.edu.my/id/eprint/21454/
http://libraryopac.utem.edu.my/webopac20/Record/0000107862
work_keys_str_mv AT najemibrahimhamadmohamed analysisofenergyusageinpusatpersatuanpelajar