Conceptual Retrofit Design Of Sustainable Energy Management System For Office Building

Conducting an energy audit in academic buildings which are directly focused on the lighting system and air conditioning system. To analyze and identify the energy consumption and efficiency of the academic building in Kolej Komuniti Tasek Gelugor is the main study throughout this project. Data colle...

Full description

Bibliographic Details
Main Author: Mohd Nasir, Mohd Zulfadly
Format: Thesis
Language:English
English
Published: 2019
Subjects:
Online Access:http://eprints.utem.edu.my/id/eprint/25530/
https://plh.utem.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=117972
Abstract Abstract here
_version_ 1855619767637901312
author Mohd Nasir, Mohd Zulfadly
author_facet Mohd Nasir, Mohd Zulfadly
author_sort Mohd Nasir, Mohd Zulfadly
description Conducting an energy audit in academic buildings which are directly focused on the lighting system and air conditioning system. To analyze and identify the energy consumption and efficiency of the academic building in Kolej Komuniti Tasek Gelugor is the main study throughout this project. Data collection includes the lighting intensity measurement and energy calculation comparison. Almost 25% of the energy consumption at campus is from the lighting usage and 60% more contributed from air conditioning usage. The saving created by lighting retrofitting is RM 8987.00 and base on the pay-back period calculated to be 6 months of return of the investment (ROI). For air conditioning system, the no-cost retrofitting procedure 10% consumption saving with 13461.4 kWh of saving. The highest saving can be achieved with “DROP IN” procedure of retrofitting procedure with 30% future electrical consumption reduced. The calculations showed that the Building Energy Index is 112.5 kWh/m2/year. The greatest BEI practice and recommended by Malaysian Standard (MS 1525) is 275 kWh /m*year. Thus, Kolej Komuniti Tasek Gelugor energy index is lower compared to recommended standards.
format Thesis
id utem-25530
institution Universiti Teknikal Malaysia Melaka
language English
English
publishDate 2019
record_format EPrints
record_pdf Restricted
spelling utem-255302022-01-06T12:20:43Z http://eprints.utem.edu.my/id/eprint/25530/ Conceptual Retrofit Design Of Sustainable Energy Management System For Office Building Mohd Nasir, Mohd Zulfadly T Technology (General) TJ Mechanical engineering and machinery Conducting an energy audit in academic buildings which are directly focused on the lighting system and air conditioning system. To analyze and identify the energy consumption and efficiency of the academic building in Kolej Komuniti Tasek Gelugor is the main study throughout this project. Data collection includes the lighting intensity measurement and energy calculation comparison. Almost 25% of the energy consumption at campus is from the lighting usage and 60% more contributed from air conditioning usage. The saving created by lighting retrofitting is RM 8987.00 and base on the pay-back period calculated to be 6 months of return of the investment (ROI). For air conditioning system, the no-cost retrofitting procedure 10% consumption saving with 13461.4 kWh of saving. The highest saving can be achieved with “DROP IN” procedure of retrofitting procedure with 30% future electrical consumption reduced. The calculations showed that the Building Energy Index is 112.5 kWh/m2/year. The greatest BEI practice and recommended by Malaysian Standard (MS 1525) is 275 kWh /m*year. Thus, Kolej Komuniti Tasek Gelugor energy index is lower compared to recommended standards. 2019 Thesis NonPeerReviewed text en http://eprints.utem.edu.my/id/eprint/25530/1/Conceptual%20Retrofit%20Design%20Of%20Sustainable%20Energy%20Management%20System%20For%20Office%20Building.pdf text en http://eprints.utem.edu.my/id/eprint/25530/2/Conceptual%20Retrofit%20Design%20Of%20Sustainable%20Energy%20Management%20System%20For%20Office%20Building.pdf Mohd Nasir, Mohd Zulfadly (2019) Conceptual Retrofit Design Of Sustainable Energy Management System For Office Building. Masters thesis, Universiti Teknikal Malaysia Melaka. https://plh.utem.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=117972
spellingShingle T Technology (General)
TJ Mechanical engineering and machinery
Mohd Nasir, Mohd Zulfadly
Conceptual Retrofit Design Of Sustainable Energy Management System For Office Building
thesis_level Master
title Conceptual Retrofit Design Of Sustainable Energy Management System For Office Building
title_full Conceptual Retrofit Design Of Sustainable Energy Management System For Office Building
title_fullStr Conceptual Retrofit Design Of Sustainable Energy Management System For Office Building
title_full_unstemmed Conceptual Retrofit Design Of Sustainable Energy Management System For Office Building
title_short Conceptual Retrofit Design Of Sustainable Energy Management System For Office Building
title_sort conceptual retrofit design of sustainable energy management system for office building
topic T Technology (General)
TJ Mechanical engineering and machinery
url http://eprints.utem.edu.my/id/eprint/25530/
https://plh.utem.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=117972
work_keys_str_mv AT mohdnasirmohdzulfadly conceptualretrofitdesignofsustainableenergymanagementsystemforofficebuilding