A telecobalt60-computed radiography verification model to improve the certainty of the irradiation

Radiotherapy remains the main treatment of cancer to date. To achieve the certainty of the irradiation, the radiotherapy must be delivered using teletherapy, which is equipped with a verification portal imaging device. However, the telecobalt60 is not equipped with the verification portal imaging de...

Description complète

Détails bibliographiques
Auteur principal: Hendrik
Format: Thèse
Langue:anglais
anglais
Publié: 2023
Sujets:
Accès en ligne:http://eprints.utem.edu.my/id/eprint/28270/
https://plh.utem.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=123878
Abstract Abstract here
_version_ 1855750122078470144
author Hendrik
author_facet Hendrik
author_sort Hendrik
description Radiotherapy remains the main treatment of cancer to date. To achieve the certainty of the irradiation, the radiotherapy must be delivered using teletherapy, which is equipped with a verification portal imaging device. However, the telecobalt60 is not equipped with the verification portal imaging device. Therefore, in the telecobalt60 utilization, the wrong site being treated errors in radiotherapy delivery are rarely verified. To solve this issue, this study aimed to determine the factors that could influence the telecobalt60-computed radiography verification model to improve the certainty of the irradiation, to develop the telecobalt60- computed radiography verification model, to formulate the standard of procedures (SOP) of the telecobalt60-computed radiography verification model, and to improve the certainty of the irradiation by existing and performing the SOP of the telecobalt60-computed radiography verification model and compare with the previous SOP of the irradiation. The research design was a mix of qualitative and quantitative methods. A qualitative study was used to determine the factors that could influence the telecobalt60-computed radiography verification model, to develop the telecobalt60-computed radiography verification model, and to formulate the SOP of the telecobalt60-computed radiography verification model. Meanwhile, a quantitative study was used to improve the certainty of the irradiation by performing the SOP of the telecobalt60-computed radiography verification model. Based on the results, the factors that could influence the telecobalt60-computed radiography verification model are the equality of the irradiation field (the scheme of simulator image, body size of the patient, and the patient positioning) and accuracy of the irradiation target factors (the set-up of the patient and teletherapy device, calibration of the teletherapy, quality of conducting the human resource, mechanical malfunctioning of the teletherapy). In developing the telecobalt60-CR verification model, formulating the SOP of the telecobalt60-CR verification model, and evaluating the improvement by the SOP of the verification model, there was significant (p<0.05) improvement of the certainty of the irradiation by existing and performing the SOP of the telecobalt60-computed radiography verification model as compared to the previous SOP of the irradiation. The conclusion was the equality of the irradiation field and accuracy of the irradiation target factors significantly (p<0.05) influenced the telecobalt60-computed radiography verification model to improve the certainty of the irradiation. The certainty of the irradiation obtained by the verification model performed by the SOP of the telecobalt60- computed radiography verification model was improved as compared to the previous SOP irradiation. The telecobalt60-CR verification model developed in this study is useful for the radiotherapy servicer and researchers to improve and sustain the survival and quality of life of cervical cancer patients.
format Thesis
id utem-28270
institution Universiti Teknikal Malaysia Melaka
language English
English
publishDate 2023
record_format EPrints
record_pdf Restricted
spelling utem-282702024-12-16T07:52:41Z http://eprints.utem.edu.my/id/eprint/28270/ A telecobalt60-computed radiography verification model to improve the certainty of the irradiation Hendrik R Medicine (General) RC Internal medicine Radiotherapy remains the main treatment of cancer to date. To achieve the certainty of the irradiation, the radiotherapy must be delivered using teletherapy, which is equipped with a verification portal imaging device. However, the telecobalt60 is not equipped with the verification portal imaging device. Therefore, in the telecobalt60 utilization, the wrong site being treated errors in radiotherapy delivery are rarely verified. To solve this issue, this study aimed to determine the factors that could influence the telecobalt60-computed radiography verification model to improve the certainty of the irradiation, to develop the telecobalt60- computed radiography verification model, to formulate the standard of procedures (SOP) of the telecobalt60-computed radiography verification model, and to improve the certainty of the irradiation by existing and performing the SOP of the telecobalt60-computed radiography verification model and compare with the previous SOP of the irradiation. The research design was a mix of qualitative and quantitative methods. A qualitative study was used to determine the factors that could influence the telecobalt60-computed radiography verification model, to develop the telecobalt60-computed radiography verification model, and to formulate the SOP of the telecobalt60-computed radiography verification model. Meanwhile, a quantitative study was used to improve the certainty of the irradiation by performing the SOP of the telecobalt60-computed radiography verification model. Based on the results, the factors that could influence the telecobalt60-computed radiography verification model are the equality of the irradiation field (the scheme of simulator image, body size of the patient, and the patient positioning) and accuracy of the irradiation target factors (the set-up of the patient and teletherapy device, calibration of the teletherapy, quality of conducting the human resource, mechanical malfunctioning of the teletherapy). In developing the telecobalt60-CR verification model, formulating the SOP of the telecobalt60-CR verification model, and evaluating the improvement by the SOP of the verification model, there was significant (p<0.05) improvement of the certainty of the irradiation by existing and performing the SOP of the telecobalt60-computed radiography verification model as compared to the previous SOP of the irradiation. The conclusion was the equality of the irradiation field and accuracy of the irradiation target factors significantly (p<0.05) influenced the telecobalt60-computed radiography verification model to improve the certainty of the irradiation. The certainty of the irradiation obtained by the verification model performed by the SOP of the telecobalt60- computed radiography verification model was improved as compared to the previous SOP irradiation. The telecobalt60-CR verification model developed in this study is useful for the radiotherapy servicer and researchers to improve and sustain the survival and quality of life of cervical cancer patients. 2023 Thesis NonPeerReviewed text en http://eprints.utem.edu.my/id/eprint/28270/1/A%20telecobalt60-computed%20radiography%20verification%20model%20to%20improve%20the%20certainty%20of%20the%20irradiation.pdf text en http://eprints.utem.edu.my/id/eprint/28270/2/A%20telecobalt60-computed%20radiography%20verification%20model%20to%20improve%20the%20certainty%20of%20the%20irradiation.pdf Hendrik (2023) A telecobalt60-computed radiography verification model to improve the certainty of the irradiation. Doctoral thesis, Universiti Teknikal Malaysia Melaka. https://plh.utem.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=123878
spellingShingle R Medicine (General)
RC Internal medicine
Hendrik
A telecobalt60-computed radiography verification model to improve the certainty of the irradiation
thesis_level PhD
title A telecobalt60-computed radiography verification model to improve the certainty of the irradiation
title_full A telecobalt60-computed radiography verification model to improve the certainty of the irradiation
title_fullStr A telecobalt60-computed radiography verification model to improve the certainty of the irradiation
title_full_unstemmed A telecobalt60-computed radiography verification model to improve the certainty of the irradiation
title_short A telecobalt60-computed radiography verification model to improve the certainty of the irradiation
title_sort telecobalt60 computed radiography verification model to improve the certainty of the irradiation
topic R Medicine (General)
RC Internal medicine
url http://eprints.utem.edu.my/id/eprint/28270/
https://plh.utem.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=123878
work_keys_str_mv AT hendrik atelecobalt60computedradiographyverificationmodeltoimprovethecertaintyoftheirradiation
AT hendrik telecobalt60computedradiographyverificationmodeltoimprovethecertaintyoftheirradiation