Condition monitoring of electric motor

Condition monitoring on electric motor is a preventive maintenance in order to avoid problems and hazard from happening to the machinery, also to prevent personal injury with the major factor is insulation resistance. In this thesis, to further discuss this issue, the developed experiment with the m...

Full description

Bibliographic Details
Main Author: Ngadiron, Zuraidah
Format: Thesis
Language:English
English
English
Published: 2007
Subjects:
Online Access:http://eprints.uthm.edu.my/2189/
Abstract Abstract here
_version_ 1855520497122410496
author Ngadiron, Zuraidah
author_facet Ngadiron, Zuraidah
author_sort Ngadiron, Zuraidah
description Condition monitoring on electric motor is a preventive maintenance in order to avoid problems and hazard from happening to the machinery, also to prevent personal injury with the major factor is insulation resistance. In this thesis, to further discuss this issue, the developed experiment with the measuring technique of the condition of electric motor on insulation resistance is used. Then, the experiment rig was developed applied to Thrige Odense Denmark 3-phase induction motor for case stud} to obserxe the condition monitoring on insulation resistance. The validity of the data was then taken using the megohmmeter and temperature indicator. The experiment is to monitor the Denmark manufactured motor condition of insulation whether is good. fair, poor or bad by following the IEEE standard procedure. This prexentixe maintenance test can be done on a monthlx. semiannual or annual basis as conditions demand. The data from the test is plotted to graph to get the trended data of the insulation. The theoretical and experiment studies include the effect of the humiditx and temperature to the insulation. Tests rig for the experimental work are developed using IEEE Standard 43-2000. IEEE Recommended Practice for Testing Insulation Resistance of Rotating Machinery and A Guide To Diagnostic Insulation Testing Above lkV by Megger Ltd. Second Edition 2002. The results have been compared to the standard and analyses are presented in graph. From the developed procedure and methods prove that the temperature affects the insulation winding at 3-phase induction motor (2 speed : 2 winding). For case study, the motor has been soaked for three days to apply flooded condition. The result shows that the motor insulation condition is even better after comparison with the standard manufactured data at 821 MH and 893 MH change to more than 999 Mfi for both winding condition after drying out experiment.
format Thesis
id uthm-2189
institution Universiti Tun Hussein Onn Malaysia
language English
English
English
publishDate 2007
record_format EPrints
record_pdf Restricted
spelling uthm-21892021-10-31T03:58:15Z http://eprints.uthm.edu.my/2189/ Condition monitoring of electric motor Ngadiron, Zuraidah TK2000-2891 Dynamoelectric machinery and auxiliaries. Including generators, motors, transformers Condition monitoring on electric motor is a preventive maintenance in order to avoid problems and hazard from happening to the machinery, also to prevent personal injury with the major factor is insulation resistance. In this thesis, to further discuss this issue, the developed experiment with the measuring technique of the condition of electric motor on insulation resistance is used. Then, the experiment rig was developed applied to Thrige Odense Denmark 3-phase induction motor for case stud} to obserxe the condition monitoring on insulation resistance. The validity of the data was then taken using the megohmmeter and temperature indicator. The experiment is to monitor the Denmark manufactured motor condition of insulation whether is good. fair, poor or bad by following the IEEE standard procedure. This prexentixe maintenance test can be done on a monthlx. semiannual or annual basis as conditions demand. The data from the test is plotted to graph to get the trended data of the insulation. The theoretical and experiment studies include the effect of the humiditx and temperature to the insulation. Tests rig for the experimental work are developed using IEEE Standard 43-2000. IEEE Recommended Practice for Testing Insulation Resistance of Rotating Machinery and A Guide To Diagnostic Insulation Testing Above lkV by Megger Ltd. Second Edition 2002. The results have been compared to the standard and analyses are presented in graph. From the developed procedure and methods prove that the temperature affects the insulation winding at 3-phase induction motor (2 speed : 2 winding). For case study, the motor has been soaked for three days to apply flooded condition. The result shows that the motor insulation condition is even better after comparison with the standard manufactured data at 821 MH and 893 MH change to more than 999 Mfi for both winding condition after drying out experiment. 2007-11 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/2189/1/ZURAIDAH%20BINTI%20NGADIRON%20-%20declaration.pdf text en http://eprints.uthm.edu.my/2189/2/ZURAIDAH%20BINTI%20NGADIRON%20-%2024p.pdf text en http://eprints.uthm.edu.my/2189/3/ZURAIDAH%20BINTI%20NGADIRON%20-%20fulltext.pdf Ngadiron, Zuraidah (2007) Condition monitoring of electric motor. Masters thesis, Universiti Tun Hussein Onn Malaysia.
spellingShingle TK2000-2891 Dynamoelectric machinery and auxiliaries. Including generators, motors, transformers
Ngadiron, Zuraidah
Condition monitoring of electric motor
thesis_level Master
title Condition monitoring of electric motor
title_full Condition monitoring of electric motor
title_fullStr Condition monitoring of electric motor
title_full_unstemmed Condition monitoring of electric motor
title_short Condition monitoring of electric motor
title_sort condition monitoring of electric motor
topic TK2000-2891 Dynamoelectric machinery and auxiliaries. Including generators, motors, transformers
url http://eprints.uthm.edu.my/2189/
work_keys_str_mv AT ngadironzuraidah conditionmonitoringofelectricmotor