A single-phase hybrid active power filter with photovoltaic application

The past several years have seen a rapid increase of power electronics-based loads connected to the distribution system. These types of loads draw nonsinusoidal current from the mains, degrading the power quality by causing harmonic distortion. This thesis proposes a single-phase hybrid active power...

पूर्ण विवरण

ग्रंथसूची विवरण
मुख्य लेखक: Tan, Perng Cheng
स्वरूप: थीसिस
भाषा:अंग्रेज़ी
प्रकाशित: 2006
विषय:
ऑनलाइन पहुंच:http://eprints.utm.my/5436/1/TanPerngChengMFKE2006.pdf
_version_ 1846215130664140800
author Tan, Perng Cheng
author_facet Tan, Perng Cheng
author_sort Tan, Perng Cheng
description The past several years have seen a rapid increase of power electronics-based loads connected to the distribution system. These types of loads draw nonsinusoidal current from the mains, degrading the power quality by causing harmonic distortion. This thesis proposes a single-phase hybrid active power filter with photovoltaic application. The proposed topology interconnects a passive high-pass filter in parallel with a shunt active power filter and a DC source that represents the photovoltaic array. The uniqueness of the proposed topology is the fact that it improves the harmonic filtering performance of a basic shunt active power filter, as well as simultaneously supplies the power from the photovoltaic array to the load. The compensation current reference for the proposed topology is obtained by using the extension instantaneous reactive-power theorem. This theorem simplifies the equations for the current reference estimation, thus leading to a more efficient implementation in digital signal processor. To generate the compensation current that follows the current reference, the fixed-band hysteresis current control method is adopted. This work describes the design of circuit topology, control system, highpass filter and compensation current reference estimation. The system is verified by simulation using MATLAB/Simulink simulation package. To validate the result, a 500 VA laboratory prototype is constructed. It is based on the dSPACE DS1104 digital signal processor. Experimental results show that the system effectively reduces the total harmonic distortion of the source current from 130.2 % to 19.6 %. Furthermore, it is demonstrated that the system can also supply active power to the load.
format Thesis
id uthm-5436
institution Universiti Teknologi Malaysia
language English
publishDate 2006
record_format eprints
spelling uthm-54362018-03-07T21:01:43Z http://eprints.utm.my/5436/ A single-phase hybrid active power filter with photovoltaic application Tan, Perng Cheng TK Electrical engineering. Electronics Nuclear engineering The past several years have seen a rapid increase of power electronics-based loads connected to the distribution system. These types of loads draw nonsinusoidal current from the mains, degrading the power quality by causing harmonic distortion. This thesis proposes a single-phase hybrid active power filter with photovoltaic application. The proposed topology interconnects a passive high-pass filter in parallel with a shunt active power filter and a DC source that represents the photovoltaic array. The uniqueness of the proposed topology is the fact that it improves the harmonic filtering performance of a basic shunt active power filter, as well as simultaneously supplies the power from the photovoltaic array to the load. The compensation current reference for the proposed topology is obtained by using the extension instantaneous reactive-power theorem. This theorem simplifies the equations for the current reference estimation, thus leading to a more efficient implementation in digital signal processor. To generate the compensation current that follows the current reference, the fixed-band hysteresis current control method is adopted. This work describes the design of circuit topology, control system, highpass filter and compensation current reference estimation. The system is verified by simulation using MATLAB/Simulink simulation package. To validate the result, a 500 VA laboratory prototype is constructed. It is based on the dSPACE DS1104 digital signal processor. Experimental results show that the system effectively reduces the total harmonic distortion of the source current from 130.2 % to 19.6 %. Furthermore, it is demonstrated that the system can also supply active power to the load. 2006-08-25 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/5436/1/TanPerngChengMFKE2006.pdf Tan, Perng Cheng (2006) A single-phase hybrid active power filter with photovoltaic application. Masters thesis, Universiti Teknologi Malaysia, Faculty of Electrical Engineering.
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Tan, Perng Cheng
A single-phase hybrid active power filter with photovoltaic application
title A single-phase hybrid active power filter with photovoltaic application
title_full A single-phase hybrid active power filter with photovoltaic application
title_fullStr A single-phase hybrid active power filter with photovoltaic application
title_full_unstemmed A single-phase hybrid active power filter with photovoltaic application
title_short A single-phase hybrid active power filter with photovoltaic application
title_sort single phase hybrid active power filter with photovoltaic application
topic TK Electrical engineering. Electronics Nuclear engineering
url http://eprints.utm.my/5436/1/TanPerngChengMFKE2006.pdf
url-record http://eprints.utm.my/5436/
work_keys_str_mv AT tanperngcheng asinglephasehybridactivepowerfilterwithphotovoltaicapplication
AT tanperngcheng singlephasehybridactivepowerfilterwithphotovoltaicapplication