Development of a new device to measure finger's mean arterial pressure

Measuring the blood pressure is a vital process in order to diagnose the health problem particularly to avoid the heart attack or stroke. Currently, there are two common procedures to test the blood pressure namely via the automated oscillometric device and the manual auscultatory device. Both oscil...

Full description

Bibliographic Details
Main Author: Chellathurai, Bumaran
Format: Thesis
Language:English
English
English
Published: 2018
Subjects:
Online Access:http://eprints.uthm.edu.my/544/
Abstract Abstract here
_version_ 1855520279181131776
author Chellathurai, Bumaran
author_facet Chellathurai, Bumaran
author_sort Chellathurai, Bumaran
description Measuring the blood pressure is a vital process in order to diagnose the health problem particularly to avoid the heart attack or stroke. Currently, there are two common procedures to test the blood pressure namely via the automated oscillometric device and the manual auscultatory device. Both oscillometric and auscultatory methods are performed on the human arm by using a blood pressure cuff. The above measurement methods are discomfort and time consuming since the cuff is placed on the human arm that involves inflation and deflation process. Hence, a new development of the Finger Mean Arterial Pressure (Finger M.A.P) device is proposed as an alternative measurement device. Instead of placing the cuff on the human arm, a new Finger M.A.P device allows us to measure the blood pressure on the finger. This type of measurement is derived from the photoplethysmography (PPG) signal which conventionally used to estimate the oxygen saturation level. A series of tests based on 10 subjects have been conducted in order to validate the Finger M.A.P device. From statistical analysis using Pearson correlation coefficient, the R value of 0.982 and 0.9416 are obtained when the data of finger’s mean arterial pressure and brachial mean arterial pressure (oscillometric based and korotkoff based respectively) are compared. These results show that the Finger M.A.P device produced sufficient signal characteristic close to the signal produced by the automated oscillometric and the manual auscultatory device. Certainly, these preliminary results show that there is a correlation between a conventional technique (i.e. via automated oscillometric device and the manual auscultatory device) and a newly proposed measurement technique (via Finger M.A.P device).
format Thesis
id uthm-544
institution Universiti Tun Hussein Onn Malaysia
language English
English
English
publishDate 2018
record_format EPrints
record_pdf Restricted
spelling uthm-5442022-08-09T03:14:36Z http://eprints.uthm.edu.my/544/ Development of a new device to measure finger's mean arterial pressure Chellathurai, Bumaran T Technology (General) Measuring the blood pressure is a vital process in order to diagnose the health problem particularly to avoid the heart attack or stroke. Currently, there are two common procedures to test the blood pressure namely via the automated oscillometric device and the manual auscultatory device. Both oscillometric and auscultatory methods are performed on the human arm by using a blood pressure cuff. The above measurement methods are discomfort and time consuming since the cuff is placed on the human arm that involves inflation and deflation process. Hence, a new development of the Finger Mean Arterial Pressure (Finger M.A.P) device is proposed as an alternative measurement device. Instead of placing the cuff on the human arm, a new Finger M.A.P device allows us to measure the blood pressure on the finger. This type of measurement is derived from the photoplethysmography (PPG) signal which conventionally used to estimate the oxygen saturation level. A series of tests based on 10 subjects have been conducted in order to validate the Finger M.A.P device. From statistical analysis using Pearson correlation coefficient, the R value of 0.982 and 0.9416 are obtained when the data of finger’s mean arterial pressure and brachial mean arterial pressure (oscillometric based and korotkoff based respectively) are compared. These results show that the Finger M.A.P device produced sufficient signal characteristic close to the signal produced by the automated oscillometric and the manual auscultatory device. Certainly, these preliminary results show that there is a correlation between a conventional technique (i.e. via automated oscillometric device and the manual auscultatory device) and a newly proposed measurement technique (via Finger M.A.P device). 2018-06 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/544/1/24p%20BUMARAN%20AL%20CHELLATHURAI.pdf text en http://eprints.uthm.edu.my/544/2/BUMARAN%20AL%20CHELLATHURAI%20COPYRIGHT%20DECLARATION.pdf text en http://eprints.uthm.edu.my/544/3/BUMARAN%20AL%20CHELLATHURAI%20WATERMARK.pdf Chellathurai, Bumaran (2018) Development of a new device to measure finger's mean arterial pressure. Masters thesis, Universiti Tun Hussein Onn Malaysia.
spellingShingle T Technology (General)
Chellathurai, Bumaran
Development of a new device to measure finger's mean arterial pressure
thesis_level Master
title Development of a new device to measure finger's mean arterial pressure
title_full Development of a new device to measure finger's mean arterial pressure
title_fullStr Development of a new device to measure finger's mean arterial pressure
title_full_unstemmed Development of a new device to measure finger's mean arterial pressure
title_short Development of a new device to measure finger's mean arterial pressure
title_sort development of a new device to measure finger s mean arterial pressure
topic T Technology (General)
url http://eprints.uthm.edu.my/544/
work_keys_str_mv AT chellathuraibumaran developmentofanewdevicetomeasurefingersmeanarterialpressure