Comparison of rhombic type micromixer to improve mixing efficiency in biomems application.

The term lab on chip and micro total analysis system stand synonymous for devices that require handling and processing of small amount of fluid to perform function such as sample preparation, separation, biosensing and detection. Constraint to the long mixing channel and miniaturized in size but ef...

Full description

Bibliographic Details
Main Author: Salleh, Mariam
Format: Thesis
Language:English
English
English
Published: 2013
Subjects:
Online Access:http://eprints.uthm.edu.my/6668/
Abstract Abstract here
_version_ 1855520624551657472
author Salleh, Mariam
author_facet Salleh, Mariam
author_sort Salleh, Mariam
description The term lab on chip and micro total analysis system stand synonymous for devices that require handling and processing of small amount of fluid to perform function such as sample preparation, separation, biosensing and detection. Constraint to the long mixing channel and miniaturized in size but efficiently mixed between fluids. In this project, the three types of rhombic geometry design were studied to characterize mixing performance between the blood sample and reagents. Pure rhombic, branch rhombic and slanted groove rhombic glass based micromixer were proposed to study the mixing performance. The simulation was obtained using CoventorWare 2010. The laminar mixing between blood sample and reagent was simulated at low Reynolds number flow (Re <<1). Reagents used are toluene-low viscosity reagent and carbolic acid- higher viscosity reagent in comparison to blood. mixing characterization will be optimized based on visualization result of the distribution field in term of viscosity. Image standard deviation (σ) is used to characterize fluid mixing; the lower σ, the better in fluids mixing properties. From study, it was found that slanted groove rhombic gained the highest mixing efficiency followed by pure rhombic and branch rhombic. This is because grooves structure can improve surface contact area thus stretch and folds the laminar flows.
format Thesis
id uthm-6668
institution Universiti Tun Hussein Onn Malaysia
language English
English
English
publishDate 2013
record_format EPrints
record_pdf Restricted
spelling uthm-66682022-03-14T01:44:25Z http://eprints.uthm.edu.my/6668/ Comparison of rhombic type micromixer to improve mixing efficiency in biomems application. Salleh, Mariam TA Engineering (General). Civil engineering (General) TA349-359 Mechanics of engineering. Applied mechanics The term lab on chip and micro total analysis system stand synonymous for devices that require handling and processing of small amount of fluid to perform function such as sample preparation, separation, biosensing and detection. Constraint to the long mixing channel and miniaturized in size but efficiently mixed between fluids. In this project, the three types of rhombic geometry design were studied to characterize mixing performance between the blood sample and reagents. Pure rhombic, branch rhombic and slanted groove rhombic glass based micromixer were proposed to study the mixing performance. The simulation was obtained using CoventorWare 2010. The laminar mixing between blood sample and reagent was simulated at low Reynolds number flow (Re <<1). Reagents used are toluene-low viscosity reagent and carbolic acid- higher viscosity reagent in comparison to blood. mixing characterization will be optimized based on visualization result of the distribution field in term of viscosity. Image standard deviation (σ) is used to characterize fluid mixing; the lower σ, the better in fluids mixing properties. From study, it was found that slanted groove rhombic gained the highest mixing efficiency followed by pure rhombic and branch rhombic. This is because grooves structure can improve surface contact area thus stretch and folds the laminar flows. 2013-06 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/6668/1/24p%20MARIAM%20SALLEH.pdf text en http://eprints.uthm.edu.my/6668/2/MARIAM%20SALLEH%20COPYRIGHT%20DECLARATION.pdf text en http://eprints.uthm.edu.my/6668/3/MARIAM%20SALLEH%20WATERMARK.pdf Salleh, Mariam (2013) Comparison of rhombic type micromixer to improve mixing efficiency in biomems application. Masters thesis, Universiti Tun Hussein Malaysia.
spellingShingle TA Engineering (General). Civil engineering (General)
TA349-359 Mechanics of engineering. Applied mechanics
Salleh, Mariam
Comparison of rhombic type micromixer to improve mixing efficiency in biomems application.
thesis_level Master
title Comparison of rhombic type micromixer to improve mixing efficiency in biomems application.
title_full Comparison of rhombic type micromixer to improve mixing efficiency in biomems application.
title_fullStr Comparison of rhombic type micromixer to improve mixing efficiency in biomems application.
title_full_unstemmed Comparison of rhombic type micromixer to improve mixing efficiency in biomems application.
title_short Comparison of rhombic type micromixer to improve mixing efficiency in biomems application.
title_sort comparison of rhombic type micromixer to improve mixing efficiency in biomems application
topic TA Engineering (General). Civil engineering (General)
TA349-359 Mechanics of engineering. Applied mechanics
url http://eprints.uthm.edu.my/6668/
work_keys_str_mv AT sallehmariam comparisonofrhombictypemicromixertoimprovemixingefficiencyinbiomemsapplication