Sizing of hybrid photovoltaic and wind system for Block A residential hostel

This Project discussed the sizing Process of stand-alone Photovoltaic (PV) and wind system to supply the required load for Residential hostel located in Parit Raja, Malaysia. Energy from renewable sources is clean, eco-friendly, efficient, and reliable. Solar and wind are gaining much importance in...

Full description

Bibliographic Details
Main Author: Salad, Yusuf Hassan
Format: Thesis
Language:English
English
English
Published: 2021
Subjects:
Online Access:http://eprints.uthm.edu.my/6988/
Abstract Abstract here
_version_ 1855520647843676160
author Salad, Yusuf Hassan
author_facet Salad, Yusuf Hassan
author_sort Salad, Yusuf Hassan
description This Project discussed the sizing Process of stand-alone Photovoltaic (PV) and wind system to supply the required load for Residential hostel located in Parit Raja, Malaysia. Energy from renewable sources is clean, eco-friendly, efficient, and reliable. Solar and wind are gaining much importance in the present world. It is important to establish renewable energy in an isolated area where the availability of fuel is costly for grid expansion. The procedure of this research was the measuring and collection of the basic meteorological data of solar radiation and wind speed for Parit Raja. The project aims to size the stand-alone system was by using manual calculation and HOMER Pro software. However, solar and wind energy are known as dependable and widely available renewable energy sources in Malaysia, but the intermittent energy sources will cause the power generator to produce a fluctuating output when it's overcast or night-time, one can't power our system utilizing a stand-alone PV system since there is no solar radiation. Similarly, the varying wind speed will affect the amount of energy generated by a standalone wind turbine system. The simulation results showed that a hybrid system consists of 58kW photovoltaic modules with one wind turbine (20 kW), 15kW inverter, and 1 kWh battery storage (48batteries, 200 Ah, and 12 V) produced electricity for a residential hostel and cost of electricity of RM0.703 per Kwh. finally, the PV system ended up being the most cost-effective solution, while also being the most efficient in terms of energy usage.
format Thesis
id uthm-6988
institution Universiti Tun Hussein Onn Malaysia
language English
English
English
publishDate 2021
record_format EPrints
record_pdf Restricted
spelling uthm-69882022-04-26T06:54:34Z http://eprints.uthm.edu.my/6988/ Sizing of hybrid photovoltaic and wind system for Block A residential hostel Salad, Yusuf Hassan TD159-168 Municipal engineering This Project discussed the sizing Process of stand-alone Photovoltaic (PV) and wind system to supply the required load for Residential hostel located in Parit Raja, Malaysia. Energy from renewable sources is clean, eco-friendly, efficient, and reliable. Solar and wind are gaining much importance in the present world. It is important to establish renewable energy in an isolated area where the availability of fuel is costly for grid expansion. The procedure of this research was the measuring and collection of the basic meteorological data of solar radiation and wind speed for Parit Raja. The project aims to size the stand-alone system was by using manual calculation and HOMER Pro software. However, solar and wind energy are known as dependable and widely available renewable energy sources in Malaysia, but the intermittent energy sources will cause the power generator to produce a fluctuating output when it's overcast or night-time, one can't power our system utilizing a stand-alone PV system since there is no solar radiation. Similarly, the varying wind speed will affect the amount of energy generated by a standalone wind turbine system. The simulation results showed that a hybrid system consists of 58kW photovoltaic modules with one wind turbine (20 kW), 15kW inverter, and 1 kWh battery storage (48batteries, 200 Ah, and 12 V) produced electricity for a residential hostel and cost of electricity of RM0.703 per Kwh. finally, the PV system ended up being the most cost-effective solution, while also being the most efficient in terms of energy usage. 2021-07 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/6988/1/24p%20YUSUF%20HASSAN%20SALAD.pdf text en http://eprints.uthm.edu.my/6988/2/YUSUF%20HASSAN%20SALAD%20COPYRIGHT%20DECLARATION.pdf text en http://eprints.uthm.edu.my/6988/3/YUSUF%20HASSAN%20SALAD%20WATERMARK.pdf Salad, Yusuf Hassan (2021) Sizing of hybrid photovoltaic and wind system for Block A residential hostel. Masters thesis, Universiti Tun Hussein Malaysia.
spellingShingle TD159-168 Municipal engineering
Salad, Yusuf Hassan
Sizing of hybrid photovoltaic and wind system for Block A residential hostel
thesis_level Master
title Sizing of hybrid photovoltaic and wind system for Block A residential hostel
title_full Sizing of hybrid photovoltaic and wind system for Block A residential hostel
title_fullStr Sizing of hybrid photovoltaic and wind system for Block A residential hostel
title_full_unstemmed Sizing of hybrid photovoltaic and wind system for Block A residential hostel
title_short Sizing of hybrid photovoltaic and wind system for Block A residential hostel
title_sort sizing of hybrid photovoltaic and wind system for block a residential hostel
topic TD159-168 Municipal engineering
url http://eprints.uthm.edu.my/6988/
work_keys_str_mv AT saladyusufhassan sizingofhybridphotovoltaicandwindsystemforblockaresidentialhostel