Optimum location and allocation of fault current limiter in distribution power system using Y-Bus matrix

The fault monitoring system is a serious part as one of the components that give the negative impact to the system. The fault needs to identify the magnitude of the nominal current, this magnitude is more than five (5) times greater than nominal current. If this happened on the system, it will cause...

وصف كامل

التفاصيل البيبلوغرافية
المؤلف الرئيسي: Zainal, Mohamad Izwan
التنسيق: أطروحة
اللغة:الإنجليزية
منشور في: 2014
الموضوعات:
الوصول للمادة أونلاين:http://eprints.utm.my/78264/1/MohamadIzwanZainalMFKE20141.pdf
_version_ 1846217880959451136
author Zainal, Mohamad Izwan
author_facet Zainal, Mohamad Izwan
author_sort Zainal, Mohamad Izwan
description The fault monitoring system is a serious part as one of the components that give the negative impact to the system. The fault needs to identify the magnitude of the nominal current, this magnitude is more than five (5) times greater than nominal current. If this happened on the system, it will cause the disaster on the Power System itself, either, system failure or, system damage. The FCL can be applied to the system for maintaining the circuit breaker operates within their limits/ratings. The Y-Bus Matrix has been implemented to analyse the optimal location of FCL for limit the fault current. This Y-Bus Matrix is identify for each buses declared as a Point of Common Coupling. Different location of fault impedance will be resulting the different location of FCL. Two categories of simulation has been used, Matlab Simulation and Y-Bus Matrix Simulation Technique as an additional support instrumentation. This project discover that FCL should be located in series at high admittance value. The analyses are verified by simulation result.
format Thesis
id uthm-78264
institution Universiti Teknologi Malaysia
language English
publishDate 2014
record_format eprints
spelling uthm-782642018-08-03T08:46:49Z http://eprints.utm.my/78264/ Optimum location and allocation of fault current limiter in distribution power system using Y-Bus matrix Zainal, Mohamad Izwan TK Electrical engineering. Electronics Nuclear engineering The fault monitoring system is a serious part as one of the components that give the negative impact to the system. The fault needs to identify the magnitude of the nominal current, this magnitude is more than five (5) times greater than nominal current. If this happened on the system, it will cause the disaster on the Power System itself, either, system failure or, system damage. The FCL can be applied to the system for maintaining the circuit breaker operates within their limits/ratings. The Y-Bus Matrix has been implemented to analyse the optimal location of FCL for limit the fault current. This Y-Bus Matrix is identify for each buses declared as a Point of Common Coupling. Different location of fault impedance will be resulting the different location of FCL. Two categories of simulation has been used, Matlab Simulation and Y-Bus Matrix Simulation Technique as an additional support instrumentation. This project discover that FCL should be located in series at high admittance value. The analyses are verified by simulation result. 2014-01 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/78264/1/MohamadIzwanZainalMFKE20141.pdf Zainal, Mohamad Izwan (2014) Optimum location and allocation of fault current limiter in distribution power system using Y-Bus matrix. Masters thesis, Universiti Teknologi Malaysia, Faculty of Electrical Engineering. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:81685
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Zainal, Mohamad Izwan
Optimum location and allocation of fault current limiter in distribution power system using Y-Bus matrix
title Optimum location and allocation of fault current limiter in distribution power system using Y-Bus matrix
title_full Optimum location and allocation of fault current limiter in distribution power system using Y-Bus matrix
title_fullStr Optimum location and allocation of fault current limiter in distribution power system using Y-Bus matrix
title_full_unstemmed Optimum location and allocation of fault current limiter in distribution power system using Y-Bus matrix
title_short Optimum location and allocation of fault current limiter in distribution power system using Y-Bus matrix
title_sort optimum location and allocation of fault current limiter in distribution power system using y bus matrix
topic TK Electrical engineering. Electronics Nuclear engineering
url http://eprints.utm.my/78264/1/MohamadIzwanZainalMFKE20141.pdf
url-record http://eprints.utm.my/78264/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:81685
work_keys_str_mv AT zainalmohamadizwan optimumlocationandallocationoffaultcurrentlimiterindistributionpowersystemusingybusmatrix