Vibration and deflection are two main parameters that always govern the constructability of long span cantilever slab. This paper present the dynamic behavior of a 12.5m long span cantilever steel-concrete composite floor of an actual new proposed construction project. STAAD PRO software was used to...

全面介绍

书目详细资料
主要作者: Ahwang, Amisah
格式: Thesis
语言:英语
出版: 2017
主题:
在线阅读:http://eprints.utm.my/78478/1/AmisahAhwangMFKA2017.pdf
_version_ 1846217926855622656
author Ahwang, Amisah
author_facet Ahwang, Amisah
author_sort Ahwang, Amisah
description Vibration and deflection are two main parameters that always govern the constructability of long span cantilever slab. This paper present the dynamic behavior of a 12.5m long span cantilever steel-concrete composite floor of an actual new proposed construction project. STAAD PRO software was used to analyze the structure subjected to both static and the dynamic loading. From the preliminary analysis using static loading, it was found that the original proposed structural configuration does not pass the deflection limit and is not constructable due to requirement for too big steel section not readily available in market. Consequently, modification to shorten the cantilever length to 6m is introduced and finally makes the structure possible to be build using a ready size of steel beams that are available in Malaysian market. In the detail dynamic analysis, excitation of dynamic loadings similar to human activity at a few random locations is applied to produced various mode shape. Results from the dynamic analysis gives acceleration on adjacent panels. The acceleration vs time graph is then used to calculate the critical natural frequency of the adjacent panels. This value of natural frequency then used to determine the range of recommended peak acceleration using the graph introduced by AISC Design Guide No. 11. It is found that the natural frequencies of the adjacent floor are in the range of 4 – 7 Hz, which is considered a low frequency floors. With the combination of low acceleration and low natural frequencies, it makes the modified floor which the new length is 6m still not comfortable to be used. Therefore, recommendation to thicken the concrete slab is proposed to increase the natural frequency of the floor, so that a comfortable construction is obtained.
format Thesis
id uthm-78478
institution Universiti Teknologi Malaysia
language English
publishDate 2017
record_format eprints
spelling uthm-784782018-08-26T11:56:28Z http://eprints.utm.my/78478/ Dynamic behaviour of long span cantilever steel-concrete composite floor Ahwang, Amisah TA Engineering (General). Civil engineering (General) Vibration and deflection are two main parameters that always govern the constructability of long span cantilever slab. This paper present the dynamic behavior of a 12.5m long span cantilever steel-concrete composite floor of an actual new proposed construction project. STAAD PRO software was used to analyze the structure subjected to both static and the dynamic loading. From the preliminary analysis using static loading, it was found that the original proposed structural configuration does not pass the deflection limit and is not constructable due to requirement for too big steel section not readily available in market. Consequently, modification to shorten the cantilever length to 6m is introduced and finally makes the structure possible to be build using a ready size of steel beams that are available in Malaysian market. In the detail dynamic analysis, excitation of dynamic loadings similar to human activity at a few random locations is applied to produced various mode shape. Results from the dynamic analysis gives acceleration on adjacent panels. The acceleration vs time graph is then used to calculate the critical natural frequency of the adjacent panels. This value of natural frequency then used to determine the range of recommended peak acceleration using the graph introduced by AISC Design Guide No. 11. It is found that the natural frequencies of the adjacent floor are in the range of 4 – 7 Hz, which is considered a low frequency floors. With the combination of low acceleration and low natural frequencies, it makes the modified floor which the new length is 6m still not comfortable to be used. Therefore, recommendation to thicken the concrete slab is proposed to increase the natural frequency of the floor, so that a comfortable construction is obtained. 2017-05 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/78478/1/AmisahAhwangMFKA2017.pdf Ahwang, Amisah (2017) Dynamic behaviour of long span cantilever steel-concrete composite floor. Masters thesis, Universiti Teknologi Malaysia, Faculty of Civil Engineering. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:108751
spellingShingle TA Engineering (General). Civil engineering (General)
Ahwang, Amisah
Dynamic behaviour of long span cantilever steel-concrete composite floor
title Dynamic behaviour of long span cantilever steel-concrete composite floor
title_full Dynamic behaviour of long span cantilever steel-concrete composite floor
title_fullStr Dynamic behaviour of long span cantilever steel-concrete composite floor
title_full_unstemmed Dynamic behaviour of long span cantilever steel-concrete composite floor
title_short Dynamic behaviour of long span cantilever steel-concrete composite floor
title_sort dynamic behaviour of long span cantilever steel concrete composite floor
topic TA Engineering (General). Civil engineering (General)
url http://eprints.utm.my/78478/1/AmisahAhwangMFKA2017.pdf
url-record http://eprints.utm.my/78478/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:108751
work_keys_str_mv AT ahwangamisah dynamicbehaviouroflongspancantileversteelconcretecompositefloor