Size-specific dose estimates for adult abdomen-pelvis computed tomography examinations in Johor

Accurate dose monitoring in computed tomography (CT) is important as CT provides high radiation exposure to the patient compared to other medical imaging modalities. The determination of size-specific dose estimate (SSDE) which takes into account the patient thickness has further facilitated radiati...

पूर्ण विवरण

ग्रंथसूची विवरण
मुख्य लेखक: Bahrud Din, Nur Ashiqin
स्वरूप: थीसिस
भाषा:अंग्रेज़ी
प्रकाशित: 2017
विषय:
ऑनलाइन पहुंच:http://eprints.utm.my/81502/1/NurAshiqinBahruddinMFS2017.pdf
_version_ 1846218256842489856
author Bahrud Din, Nur Ashiqin
author_facet Bahrud Din, Nur Ashiqin
author_sort Bahrud Din, Nur Ashiqin
description Accurate dose monitoring in computed tomography (CT) is important as CT provides high radiation exposure to the patient compared to other medical imaging modalities. The determination of size-specific dose estimate (SSDE) which takes into account the patient thickness has further facilitated radiation dose calculation in medical field. Present study has been conducted to determine firstly the difference between the average patient size and polymethymethacrylate phantom size, secondly the effects of various patient dimensions on the SSDE, and finally to verify the relationship between the SSDE and the volume CT dose index (CTDIvol), as well as that of between the SSDE and the patient size. One hundred abdomen-pelvis CT images have been utilized for coefficient of variation (CV) analysis using different patients’ thickness measurements. Descriptive statistics and Mann-Whitney test have been used to obtain the significant difference, p values. Simple linear regression model was plotted to determine the correlation between the SSDE and CTDIvol, as well as that of between the SSDE and patient’s thickness by referring to the summation of anterior-posterior and lateral (AP+Lateral) diameter. Routine abdomen-pelvis protocols considered in this study are in agreement with guidelines with a mean SSDE and CTDIvol of 15.5 ± 4.1 mGy and 11.4 ± 4.6 mGy, respectively. The SSDEs measured on the axial image and localizer radiograph show no significant difference, while the SSDEs derived from AP+Lateral diameter show a lower CV compared to other size descriptors, thus the latter is recommended to be used in the future SSDE calculation. Results show that the SSDE provides a better measure of the patient radiation dose value than the CTDIvol. It reduces the underestimation and overestimation problems of using phantoms in calculation of the CTDIvol. In conclusion, a promising approach using the SSDE as a measure of patient radiation dose can provide accurate dose estimation in clinical study compared to other approach based on the CTDIvol.
format Thesis
id uthm-81502
institution Universiti Teknologi Malaysia
language English
publishDate 2017
record_format eprints
spelling uthm-815022019-08-23T05:19:16Z http://eprints.utm.my/81502/ Size-specific dose estimates for adult abdomen-pelvis computed tomography examinations in Johor Bahrud Din, Nur Ashiqin QC Physics Accurate dose monitoring in computed tomography (CT) is important as CT provides high radiation exposure to the patient compared to other medical imaging modalities. The determination of size-specific dose estimate (SSDE) which takes into account the patient thickness has further facilitated radiation dose calculation in medical field. Present study has been conducted to determine firstly the difference between the average patient size and polymethymethacrylate phantom size, secondly the effects of various patient dimensions on the SSDE, and finally to verify the relationship between the SSDE and the volume CT dose index (CTDIvol), as well as that of between the SSDE and the patient size. One hundred abdomen-pelvis CT images have been utilized for coefficient of variation (CV) analysis using different patients’ thickness measurements. Descriptive statistics and Mann-Whitney test have been used to obtain the significant difference, p values. Simple linear regression model was plotted to determine the correlation between the SSDE and CTDIvol, as well as that of between the SSDE and patient’s thickness by referring to the summation of anterior-posterior and lateral (AP+Lateral) diameter. Routine abdomen-pelvis protocols considered in this study are in agreement with guidelines with a mean SSDE and CTDIvol of 15.5 ± 4.1 mGy and 11.4 ± 4.6 mGy, respectively. The SSDEs measured on the axial image and localizer radiograph show no significant difference, while the SSDEs derived from AP+Lateral diameter show a lower CV compared to other size descriptors, thus the latter is recommended to be used in the future SSDE calculation. Results show that the SSDE provides a better measure of the patient radiation dose value than the CTDIvol. It reduces the underestimation and overestimation problems of using phantoms in calculation of the CTDIvol. In conclusion, a promising approach using the SSDE as a measure of patient radiation dose can provide accurate dose estimation in clinical study compared to other approach based on the CTDIvol. 2017 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/81502/1/NurAshiqinBahruddinMFS2017.pdf Bahrud Din, Nur Ashiqin (2017) Size-specific dose estimates for adult abdomen-pelvis computed tomography examinations in Johor. Masters thesis, Universiti Teknologi Malaysia. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:124981
spellingShingle QC Physics
Bahrud Din, Nur Ashiqin
Size-specific dose estimates for adult abdomen-pelvis computed tomography examinations in Johor
title Size-specific dose estimates for adult abdomen-pelvis computed tomography examinations in Johor
title_full Size-specific dose estimates for adult abdomen-pelvis computed tomography examinations in Johor
title_fullStr Size-specific dose estimates for adult abdomen-pelvis computed tomography examinations in Johor
title_full_unstemmed Size-specific dose estimates for adult abdomen-pelvis computed tomography examinations in Johor
title_short Size-specific dose estimates for adult abdomen-pelvis computed tomography examinations in Johor
title_sort size specific dose estimates for adult abdomen pelvis computed tomography examinations in johor
topic QC Physics
url http://eprints.utm.my/81502/1/NurAshiqinBahruddinMFS2017.pdf
url-record http://eprints.utm.my/81502/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:124981
work_keys_str_mv AT bahruddinnurashiqin sizespecificdoseestimatesforadultabdomenpelviscomputedtomographyexaminationsinjohor