Convection heat transfer in curved triangular duct - an experimental study
Also available in printed version
| 第一著者: | |
|---|---|
| その他の著者: | |
| フォーマット: | Bachelor thesis |
| 出版事項: |
Universiti Teknologi Malaysia
2025
|
| 主題: | |
| オンライン・アクセス: | https://utmik.utm.my/handle/123456789/103597 |
| Abstract | Abstract here |
| _version_ | 1854975039739265024 |
|---|---|
| author | Amir Shafiq Adham |
| author2 | Amer Nordin Darus, supervisor |
| author_facet | Amer Nordin Darus, supervisor Amir Shafiq Adham |
| author_sort | Amir Shafiq Adham |
| description | Also available in printed version |
| format | Bachelor thesis |
| id | utm-123456789-103597 |
| institution | Universiti Teknologi Malaysia |
| publishDate | 2025 |
| publisher | Universiti Teknologi Malaysia |
| record_format | dspace |
| record_pdf | Abstract |
| spelling | utm-123456789-1035972025-08-20T15:26:14Z Convection heat transfer in curved triangular duct - an experimental study Amir Shafiq Adham Amer Nordin Darus, supervisor Mechanical engineering Also available in printed version A convective heat transfer in curved triangular duct, an experimental study under steady and laminar flow condition is presented. The study covers two different type of duct which is straight triangular duct and 90º curved triangular duct. The main objective of this study is to determine the effect of curvature in the process of heat transfer in non circular tube. Besides, this study also determines the Nusselt number correlation for the bended duct and to establish the effect of Reynolds number on the Nusselt number. All data obtained at various air velocities and Reynolds numbers for temperatures were tabulated. The obtaining data are been shown in graphs that had been plotted. Analysis was made and we found that the convective heat transfer coefficient for the bended duct is higher as compared to the straight duct. It is also found that the Nusselt number is increasing directly proportional to the Reynolds number. The value of the correlation is Nu = 0.107Re1.1895 for the 90º curved triangular duct and Nu = 2.068Re0.7498 for the straight triangular duct. Finally, recommendations to improve the accuracy of the results for further study also are included in this thesis fahmimoksen UTM 66 p. Project Paper (Sarjana Muda Kejuruteraan (Mekanikal)) - Universiti Teknologi Malaysia, 2013 2025-04-10T06:53:03Z 2025-04-10T06:53:03Z 2013 Bachelor thesis https://utmik.utm.my/handle/123456789/103597 valet-20160313-120727 vital:85145 Closed Access UTM Complete Unpublished application/pdf Universiti Teknologi Malaysia |
| spellingShingle | Mechanical engineering Amir Shafiq Adham Convection heat transfer in curved triangular duct - an experimental study |
| thesis_level | Other |
| title | Convection heat transfer in curved triangular duct - an experimental study |
| title_full | Convection heat transfer in curved triangular duct - an experimental study |
| title_fullStr | Convection heat transfer in curved triangular duct - an experimental study |
| title_full_unstemmed | Convection heat transfer in curved triangular duct - an experimental study |
| title_short | Convection heat transfer in curved triangular duct - an experimental study |
| title_sort | convection heat transfer in curved triangular duct an experimental study |
| topic | Mechanical engineering |
| url | https://utmik.utm.my/handle/123456789/103597 |
| work_keys_str_mv | AT amirshafiqadham convectionheattransferincurvedtriangularductanexperimentalstudy |