Improving lateral stiffness of tall building structures using Outriggers and Belt Walls
Also available in printed version : TA654.5 M64 2008 raf
| 主要作者: | |
|---|---|
| 其他作者: | |
| 格式: | Bachelor thesis |
| 語言: | 英语 |
| 出版: |
Universiti Teknologi Malaysia
2025
|
| 主題: | |
| 在線閱讀: | https://utmik.utm.my/handle/123456789/113502 |
| Abstract | Abstract here |
| _version_ | 1854975096139022336 |
|---|---|
| author | Mohd. Asamudin A. Rahman |
| author2 | Abdul Kadir Marsono, supervisor |
| author_facet | Abdul Kadir Marsono, supervisor Mohd. Asamudin A. Rahman |
| author_sort | Mohd. Asamudin A. Rahman |
| description | Also available in printed version : TA654.5 M64 2008 raf |
| format | Bachelor thesis |
| id | utm-123456789-113502 |
| institution | Universiti Teknologi Malaysia |
| language | English |
| publishDate | 2025 |
| publisher | Universiti Teknologi Malaysia |
| record_format | dspace |
| record_pdf | Abstract |
| spelling | utm-123456789-1135022025-08-21T08:15:24Z Improving lateral stiffness of tall building structures using Outriggers and Belt Walls Mohd. Asamudin A. Rahman Abdul Kadir Marsono, supervisor Tall buildings Wind-pressure Also available in printed version : TA654.5 M64 2008 raf Many tall buildings have been built in major cities due to rapid development of new building materials and construction technology. In any slender structures, the most thing that be concerned, is the building shall not exceed the displacement limit when it comes to resist lateral loading. Improving the lateral resisting system becomes major concern when buildings increase in height. A study was conducted to make improvement in lateral stiffness for tall building structures in order to find most optimum location for stiffness element. Analyses were carried out for six cases of wind loading to compare value of displacement for five selected model consists of Outrigger and Belt Wall System located at systematically incremented height of the structure. The behaviour of the structural systems was studied through their deflection characteristic upon loading. The results showed that with the addition of structural system as bracing to an origin of model at specific floor, observed a significant decrease in displacement laterally. It also indicates that the Outrigger and Belt Wall Structural System gives the solutions in terms of improvements to the resistance of the lateral displacements to comply with Serviceability Limit State for tall buildings atiff UTM 142 p. Project Paper (Sarjana Muda Kejuruteraan (Awam - Struktur dan Bahan)) - Universiti Teknologi Malaysia, 2008 2025-04-18T07:08:08Z 2025-04-18T07:08:08Z 2008-04 Bachelor thesis https://utmik.utm.my/handle/123456789/113502 valet-20150329-143528 vital:75632 ENG Closed Access UTM Complete Completion Unpublished application/pdf Universiti Teknologi Malaysia |
| spellingShingle | Tall buildings Wind-pressure Mohd. Asamudin A. Rahman Improving lateral stiffness of tall building structures using Outriggers and Belt Walls |
| thesis_level | Other |
| title | Improving lateral stiffness of tall building structures using Outriggers and Belt Walls |
| title_full | Improving lateral stiffness of tall building structures using Outriggers and Belt Walls |
| title_fullStr | Improving lateral stiffness of tall building structures using Outriggers and Belt Walls |
| title_full_unstemmed | Improving lateral stiffness of tall building structures using Outriggers and Belt Walls |
| title_short | Improving lateral stiffness of tall building structures using Outriggers and Belt Walls |
| title_sort | improving lateral stiffness of tall building structures using outriggers and belt walls |
| topic | Tall buildings Wind-pressure |
| url | https://utmik.utm.my/handle/123456789/113502 |
| work_keys_str_mv | AT mohdasamudinarahman improvinglateralstiffnessoftallbuildingstructuresusingoutriggersandbeltwalls |