Analysis on the impact of delta T to the performance of chiller

Also available in printed version

書誌詳細
第一著者: Yeo, Zhi Hao
その他の著者: Lim, Jeng Shiun, supervisor
フォーマット: Master's thesis
言語:英語
出版事項: Universiti Teknologi Malaysia 2025
主題:
オンライン・アクセス:https://utmik.utm.my/handle/123456789/40190
Abstract Abstract here
_version_ 1854975088479174656
author Yeo, Zhi Hao
author2 Lim, Jeng Shiun, supervisor
author_facet Lim, Jeng Shiun, supervisor
Yeo, Zhi Hao
author_sort Yeo, Zhi Hao
description Also available in printed version
format Master's thesis
id utm-123456789-40190
institution Universiti Teknologi Malaysia
language English
publishDate 2025
publisher Universiti Teknologi Malaysia
record_format dspace
record_pdf Abstract
spelling utm-123456789-401902025-08-21T06:18:06Z Analysis on the impact of delta T to the performance of chiller Yeo, Zhi Hao Lim, Jeng Shiun, supervisor Chemical engineering Also available in printed version Chiller systems had become commonly used for large residential or commercial buildings. However, the energy consumption of the chiller system also occupied a large portion of the total energy consumption of the building. Therefore, it is very important to ensure the chiller system is able to work in the most energy efficient condition to reduce the electricity bill of the building. The reduction in the electricity bill is not only able to reduce the operating cost of the building, it also would be able to decrease the impact of the chiller system to the environment. Therefore, in order to achieve this objective, many research has been done to find out the energy saving measures to increase the energy efficiency of the chiller system. According to the research, increase temperature difference of chilled water is able to increase the energy efficiency of chiller system. However, many of the studies only concentrate on electricity saving. The trade-ofFthat came together with these savings did not take into account. Thus, this research aims to develop a model to evaluate the energy saving capability of increase AT of chilled water to the chiller system and the impact of AT of chilled water to the performance of the system. The research methodology includes: (1) Modeling of energy consumption of the chiller system (2) Validate model with case study (3) Manipulate the AT of chilled water and (4) Results analysis. At the end of this research, the increase of AT of chilled water is found to be able to reduce the energy consumption of the chilled water pump, which would increase the energy efficiency of the chiller system. For example, by increasing the AT of chilled water from 5°C to 8°C, the user would be able to save 6.41% of total energy consumption of the chiller system. In other word, the user could be able to reduce up to 6.33% of their electricity utility bill and greenhouse gases released per year. However, the increase of AT of chilled water would also increase the size required for cooling coil of AHU. Therefore, when implementing these improvement measures, the user would have to check whether the performance of AHU that connected to the chiller system is still able to be maintained at an acceptable level. shafika UTM 59 p. Thesis (Sarjana Sains (Pengurusan Tenaga)) - Universiti Teknologi Malaysia, 2022 2025-03-06T06:59:03Z 2025-03-06T06:59:03Z 2022 Master's thesis https://utmik.utm.my/handle/123456789/40190 vital:152283 valet-20230621-145014 ENG Closed Access UTM Complete Unpublished Completion application/pdf Universiti Teknologi Malaysia
spellingShingle Chemical engineering
Yeo, Zhi Hao
Analysis on the impact of delta T to the performance of chiller
thesis_level Master
title Analysis on the impact of delta T to the performance of chiller
title_full Analysis on the impact of delta T to the performance of chiller
title_fullStr Analysis on the impact of delta T to the performance of chiller
title_full_unstemmed Analysis on the impact of delta T to the performance of chiller
title_short Analysis on the impact of delta T to the performance of chiller
title_sort analysis on the impact of delta t to the performance of chiller
topic Chemical engineering
url https://utmik.utm.my/handle/123456789/40190
work_keys_str_mv AT yeozhihao analysisontheimpactofdeltattotheperformanceofchiller